EasyManuals Logo

Midea MFE-60ARN1-RB4W User Manual

Midea MFE-60ARN1-RB4W
57 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #55 background imageLoading...
Page #55 background image
52
9.3.12 Temperature protection of compressor discharge
Temperature protection of
compressor discharge
Check whether the
compressor discharge temp.
is more than 115°C ?
Check whether the wiring
connection is right between
compressor discharge temp.
sensor and PCB according
to wiring diagrams?
Method: Check whether the
resistance of compressor
discharge temp. sensor is
right refer to the Appendix 2
No
Yes
Yes
Trouble is solved
No
Judge: The
discharge temp.
sensor is broken
Check whether the
refrigerant is leak
Correct the wiring connection
Stop leaking and add refrigerant
Replace the compressor discharge temp. sensor
No
Yes
Replace outdoor main board
Yes

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Midea MFE-60ARN1-RB4W and is the answer not in the manual?

Midea MFE-60ARN1-RB4W Specifications

General IconGeneral
BrandMidea
ModelMFE-60ARN1-RB4W
CategoryAir Conditioner
LanguageEnglish

Related product manuals