1.  Before Installation ........................................................................4
2.  Choosing an Installation Site ......................................................4
3.  Indoor Unit Installation..................................................................4
4.  Refrigerant Piping Installation ......................................................9
5.  Water Discharge Piping Installation ...........................................10
6.  Electrical Wiring .........................................................................10
7.  On-site Configuration ............................................................... 13
8.  Test Run.................................................................................... 14
9.  Part Names .............................................................................. 15
11. Air Conditioner Operations and Performance ........................... 16
12. Adjusting Air Flow Direction ...................................................... 17
13. Maintenance.............................................................................. 17
14. Symptoms That Are Not Faults ................................................ 18
15. Troubleshooting ........................................................................ 18
Safety Precautions
Read carefully before you install the air conditioner to make sure that 
the installation is correct.
There are two types of precautions as described below:
         Warning: Failure to comply may lead to death or serious injury.
         Caution: Failure to comply may lead to injury or damage of the 
unit. Depending on the situation, this may also lead to serious injury.
Once the installation is completed, and the unit has been tested and 
verified to be operating normally, please explain to the customer how 
to  use  and  maintain  the  unit  according  to  this  manual.  In  addition, 
make sure that the manual is kept properly for future reference.
•
 
•  Install  the air  conditioner  according  to  the  steps  described  in  this 
manual.  Improper  installation  may  cause  water  leakage,  electric 
shock, or fire.
•  For  installation  in  smaller  rooms,  you  must  adopt  the  relevant 
measures to prevent the refrigerant  concentration from exceeding 
the limit. Please consult the sales agent on the relevant measures 
required. A high concentration of refrigerant in an airtight space can 
cause oxygen insufficiency (anoxia).
•  Make sure the required parts and accessories are installed. Using 
unspecified  parts  may  cause  the  air  conditioner  to  malfunction  or 
drop, as well as water leakage, electric shock, and fire.
•  Mount the air conditioner in a place that is sturdy enough to bear its 
weight. If the base is not secured properly, the air conditioner may 
drop leading to damages and injuries.
•  Take in full consideration  to the effects of strong winds,  typhoons 
and  earthquakes,  and reinforce  the  installation.  Improper  installa-
tion may cause the air conditioner to drop leading to accidents.
•  Make  sure  a  standalone  circuit  is  used  for  the  power  supply.  All 
electrical parts must comply with the local laws and regulations, and 
what is stated in this installation manual. The installation works must 
be carried out by a professional and qualified electrician. Insufficient 
capacity or improper electrical works can lead to electric shock or fire.
•  Use only electrical cables that fulfil the specifications. All wiring on 
site must be carried out in accordance with the connection diagram 
attached to
 the product. Make sure that there are no external forces 
acting on the terminals and wires. Improper wiring and installation 
may cause a fire.
•  Make sure the power cord, communication and controller wiring are 
straight and level when you are working on the connections, and the 
cover  on  the  electric  box  is  tight.  If  the  electric  box  is  not  closed 
properly,  it  may  lead  to  electric  shock,  fire  or  overheating  of 
electrical components.
•  If  the  refrigerant  leaks  during  installation,  open  the  doors  and 
windows immediately to ventilate the area. Refrigerant can produce 
toxic gases when in contact with fire.
•  Switch  off  the  power  supply  before  touching  any  electrical 
component.
•  To prevent electrical shock, do not touch a switch with wet hands. 
•  Do not come in direct contact with the refrigerant leaking from the 
connections of refrigerant piping. Otherwise, it may lead to frostbite.
•  The air conditioner must be grounded. Do not connect the earth line 
(ground)  to  gas  piping,  water  piping,  lightning  rods  or  telephone 
earth lines.  Improper  grounding  can lead  to  electric  shock or fire, 
and  may  cause  mechanical  failure  due  to  current  surges  from 
lightning and so on.
•  The earth leakage circuit breaker must be installed. There is a risk 
of  electric  shock  or  fire  if  the  earth  leakage  circuit  breaker  is  not 
installed.
1
Warning
Installation Manual
Contents
Installation, maintenance and cleaning the filter work must be 
carried out by professional installers. Refrain from doing it yourself. 
Improper installation may cause water leakage, electric shock, or 
fire.
10. The Explain Of The Display Panel..............................................15
The appliance shall be installed in accordance with national wiring 
regulations.
The appliance must be installed 2,3m above floor.
If the supply cord is damaged, it must be replaced by the 
manufacturer or its service agent or a similarly qualified person in 
order to avoid a hazard.
An all-pole disconnection switch having a contact separation of at 
least 3mm in all poles should be connected in fixed wiring.
The temperature of refrigerant circuit will be high, please keep the 
interconnection cable away from the copper tube.
The  power cord type designation is H05RN-For above/H07RN-F.
•
•
•
•
•
•
Accessories........................................................................................3
Installation Manual..............................................................................1
Check the power supply before installation. Ensure that the power 
supply must be reliably grounded following local, state and National 
Electrical Codes. If not, for example, if the ground wire  is detected  
charged, installation is prohibited before it is rectified. Otherwise, 
there is  a risk of fire and electric shock, causing physical injury or 
death. 
Check the electric wire, water and gas pipeline layout inside the 
wall, floor and ceiling before installation. Do not implement drilling 
unless confirm safety with the user, especially for the hidden 
power wire. An electroprobe can be used to test whether a wire is 
passing by at the drilling location, to prevent physical injury or 
death caused by insulation broken cords.
•
•