EasyManua.ls Logo

Midea MKB-300 - Page 13

Midea MKB-300
59 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MCAC-KTSM-2007-2 Specifications
Four Way Cassette Type 11
Remark: 1. All performance data above is based upon 0Pa ambient static pressure.
2. Cooling capacity test condition: air inlet Temp. : 27DB/19.5WB, water inlet Temp. 7,
water Temp. difference 5.
3. Heating capacity test condition:
Air inlet Temp. 21DB, water inlet Temp. 60 DB
The volume of air and water is same as cooling.
4. Noise level is tested in full-anechoic room.
TYPE
MKA-1500
MKA-1200
Airflow
CFM
1500
1200
m
3
/h
2500
2000
Cooling Capacity
W
11556
9849
Btu/h
39240
33440
Heating Capacity
W
14920
13745
Btu/h
51000
46810
Noise
dB(A)
45
45
Water flow
LPH
2388
1928
Water resistance
kPa
46
44
Indoor
Coil
Number of rows
2
Tube pitch(a)x row pitch(b)
mm
25.4×22
Fin spacing
mm
1.3
Fin type
Hydrophilic aluminum
Tube outside dia.and type
mm
φ7innergroove tube
Coil length x height x width
mm
2000×250×27
Number of circuits
6
Fan
motor
Type
Low noise 3 speed fan motor
Number
1
Model
YDK110-6
Input
W
190
180
Capacitor
uF
5
Indoor
unit
Dimension (W*H*D)
mm
840×310×840
Packing (W*H*D)
mm
1020×410×930
Net/Gross weight
kg
40/50
Panel
Dimension (W*H*D)
mm
950×40×950
Packing (W*H*D)
mm
1030×145×1030
Net/Gross weight
kg
6/11
Control mode
wired controller(optional) ,
remote controller (standard)
Pipe
Water-inlet pipe
RC3/4” internal thread
Water-return pipe
RC3/4” internal thread
Condensation water-outlet pipe
EVA+LDPE 3/4” external thread