16 Capacity Tables
Heating Capacity:
Remark:
Δt: Temperature Difference () ; TH: Total Heating Capacity (kW);
WF: Water Flow (m
3
/h); WPD: Water Pressure Drop (kPa)
MKT3H-800G70
Δt
Air inlet temp. (20 DB)
Water inlet temp. ()
35
40
45
50
55
60
65
70
TH
WF
WPD
TH
WF
WPD
TH
WF
WPD
TH
WF
WPD
TH
WF
WPD
TH
WF
WPD
TH
WF
WPD
TH
WF
WPD
10
3.29
0.28
0.4
5.16
0.44
1.0
7.14
0.61
1.9
9.01
0.77
3.0
10.89
0.94
4.4
12.81
1.10
6.1
14.65
1.26
8.0
16.50
1.42
10.1
8
3.65
0.39
0.8
5.68
0.61
1.9
7.60
0.82
3.4
9.48
1.02
5.2
11.31
1.22
7.4
13.15
1.41
10.0
15.00
1.61
13.1
16.85
1.81
16.5
6
4.22
0.61
1.8
6.15
0.88
3.9
7.97
1.14
6.6
9.90
1.42
10.1
11.77
1.69
14.3
13.62
1.95
19.1
15.35
2.20
24.3
17.31
2.48
30.9
MKT3H-1000G70
Δt
Air inlet temp. (20 DB)
Water inlet temp. ()
35
40
45
50
55
60
65
70
TH
WF
WPD
TH
WF
WPD
TH
WF
WPD
TH
WF
WPD
TH
WF
WPD
TH
WF
WPD
TH
WF
WPD
TH
WF
WPD
10
4.52
0.39
1.5
7.09
0.61
3.8
9.81
0.84
7.3
12.38
1.06
11.6
14.96
1.29
16.9
17.59
1.51
23.4
20.13
1.73
30.6
22.67
1.95
38.8
8
5.01
0.54
3.0
7.80
0.84
7.2
10.45
1.12
12.9
13.03
1.40
20.0
15.53
1.67
28.5
18.07
1.94
38.5
20.61
2.22
50.1
23.14
2.49
63.2
6
5.80
0.83
7.1
8.45
1.21
15.0
10.95
1.57
25.2
13.60
1.95
38.8
16.17
2.32
54.8
18.70
2.68
73.3
21.08
3.02
93.2
23.78
3.41
118.5
MKT3H-1200G70
Δt
Air inlet temp. (20 DB)
Water inlet temp. ()
35
40
45
50
55
60
65
70
TH
WF
WPD
TH
WF
WPD
TH
WF
WPD
TH
WF
WPD
TH
WF
WPD
TH
WF
WPD
TH
WF
WPD
TH
WF
WPD
10
5.08
0.44
1.5
7.97
0.69
3.7
11.04
0.95
7.1
13.93
1.20
11.3
16.83
1.45
16.5
19.79
1.70
22.8
22.65
1.95
29.9
25.50
2.19
37.9
8
5.63
0.61
2.9
8.77
0.94
7.0
11.75
1.26
12.6
14.66
1.58
19.6
17.48
1.88
27.8
20.33
2.19
37.6
23.18
2.49
48.9
26.03
2.80
61.7
6
6.53
0.94
6.9
9.50
1.36
14.6
12.32
1.77
24.6
15.30
2.19
37.9
18.19
2.61
53.5
21.04
3.02
71.7
23.72
3.40
91.0
26.75
3.83
115.8
MKT3H-1400G70
Δt
Air inlet temp. (20 DB)
Water inlet temp. ()
35
40
45
50
55
60
65
70
TH
WF
WPD
TH
WF
WPD
TH
WF
WPD
TH
WF
WPD
TH
WF
WPD
TH
WF
WPD
TH
WF
WPD
TH
WF
WPD
10
6.08
0.52
1.7
9.53
0.82
4.2
13.20
1.14
8.1
16.66
1.43
12.9
20.13
1.73
18.8
23.67
2.04
26.0
27.09
2.33
34.1
30.50
2.62
43.2
8
6.74
0.72
3.3
10.49
1.13
8.0
14.06
1.51
14.3
17.53
1.88
22.3
20.90
2.25
31.7
24.31
2.61
42.9
27.73
2.98
55.8
31.14
3.35
70.4
6
7.81
1.12
7.9
11.37
1.63
16.7
14.74
2.11
28.0
18.30
2.62
43.2
21.76
3.12
61.1
25.17
3.61
81.7
28.37
4.07
103.9
31.99
4.59
132.1
MKT3H-1600G100
Δt
Air inlet temp. (20 DB)
Water inlet temp. ()
35
40
45
50
55
60
65
70
TH
WF
WPD
TH
WF
WPD
TH
WF
WPD
TH
WF
WPD
TH
WF
WPD
TH
WF
WPD
TH
WF
WPD
TH
WF
WPD
10
7.14
0.61
2.8
11.20
0.96
6.9
15.51
1.33
13.1
19.57
1.68
20.9
23.66
2.03
30.6
27.81
2.39
42.2
31.82
2.74
55.3
35.83
3.08
70.1
8
7.92
0.85
5.4
12.33
1.33
13.0
16.51
1.78
23.3
20.60
2.21
36.2
24.56
2.64
51.5
28.57
3.07
69.6
32.58
3.50
90.5
36.59
3.93
114.2
6
9.17
1.31
12.8
13.36
1.91
27.1
17.32
2.48
45.5
21.50
3.08
70.1
25.56
3.66
99.1
29.57
4.24
132.6
33.33
4.78
168.5
37.59
5.39
214.3
MKT3H-1800G100