60Hz R410A ClimaMaster Tropical Rooftop Package Unit MCAC-RTSM-2015-01
42
9.9 Cooling capacity for 20Ton:
Air Flow(CFM)
6800
7600
8400
9200
Ent(DB)
(
o
F)
75
80
85
90
75
80
85
90
75
80
85
90
75
80
85
90
Ambient Temperature
85
61
TGC
209.7
212.3
222.1
234.9
215.6
220.3
230.0
242.9
218.0
223.7
238.2
249.4
227.0
230.0
243.0
252.6
SHC
167.3
199.5
215.2
227.7
176.9
212.3
222.9
235.4
186.7
216.8
230.8
241.7
194.8
222.9
235.6
244.9
67
TGC
235.7
238.7
241.4
244.8
242.9
244.7
246.1
247.8
246.0
247.9
249.4
251.3
247.9
249.4
252.6
254.3
SHC
131.9
162.4
191.5
222.1
138.1
168.9
201.1
231.7
140.5
173.8
207.6
241.4
143.8
178.7
214.0
249.4
73
TGC
249.4
254.3
257.5
260.8
252.3
255.9
260.8
263.8
255.6
259.1
262.2
265.5
259.1
263.4
266.6
269.9
SHC
89.0
121.5
148.1
173.8
90.8
124.4
151.6
176.7
92.6
125.6
154.3
183.4
94.2
127.0
156.3
188.6
95
61
TGC
196.2
201.1
210.9
225.3
198.8
207.6
220.5
233.3
206.0
210.9
227.0
239.8
210.9
218.8
233.3
244.7
SHC
159.2
191.5
204.3
218.4
168.9
199.1
211.4
223.7
178.7
204.3
219.9
232.4
186.7
212.1
226.1
237.1
67
TGC
220.5
223.7
227.0
231.7
230.0
233.6
234.9
236.5
238.2
240.0
241.6
242.9
239.0
242.2
244.3
247.1
SHC
125.6
156.1
186.7
217.2
131.1
164.1
196.4
230.0
136.4
169.1
206.0
239.8
140.3
177.1
214.0
227.1
73
TGC
243.0
246.1
249.2
252.6
244.8
247.6
251.5
255.9
247.1
250.4
253.6
255.2
252.0
256.9
260.1
263.4
SHC
84.8
116.6
145.2
172.2
86.7
120.8
149.3
178.7
88.5
123.0
153.0
183.4
90.3
125.1
156.1
188.3
105
61
TGC
182.1
187.0
196.7
213.0
188.6
193.5
209.7
219.5
191.9
200.0
217.9
232.5
196.7
208.1
224.4
237.4
SHC
151.6
181.2
190.6
206.4
162.6
187.5
203.2
212.7
172.4
193.8
211.1
225.3
178.7
201.7
217.4
230.0
67
TGC
209.7
213.0
217.9
219.5
211.4
216.2
222.7
226.0
222.7
226.0
229.2
232.5
227.6
230.9
234.1
237.4
SHC
118.6
149.6
180.3
212.5
137.6
157.7
191.5
202.7
129.1
165.7
201.1
232.5
134.0
172.2
210.9
227.4
73
TGC
239.0
240.6
242.2
243.9
242.2
243.9
245.5
248.7
245.5
247.1
248.7
250.4
247.1
248.7
250.4
253.6
SHC
80.2
111.4
141.2
169.1
82.2
115.6
146.2
177.1
83.8
119.5
150.3
181.8
85.6
121.2
154.2
190.2
115
61
TGC
165.9
172.4
188.6
204.9
170.7
180.5
196.7
213.0
175.6
187.0
204.9
221.1
180.5
193.5
211.4
226.0
SHC
144.9
167.0
182.8
198.5
154.3
174.9
190.6
206.4
162.6
181.2
198.5
214.3
174.5
187.5
204.8
219.0
67
TGC
196.7
200.0
201.6
204.9
198.4
203.2
206.5
209.7
209.7
213.0
217.9
221.1
214.6
217.9
221.1
227.7
SHC
123.6
143.4
174.0
204.9
130.1
152.0
185.4
209.7
136.6
159.4
193.5
221.1
128.2
167.5
206.5
226.0
73
TGC
222.7
226.0
229.2
230.9
229.2
232.5
234.1
235.7
234.1
235.7
237.4
239.0
235.7
237.4
239.0
240.6
SHC
75.7
106.7
137.4
167.5
77.5
112.2
143.1
174.0
81.4
115.5
149.6
183.7
81.4
120.4
152.9
187.0
125
61
TGC
156.1
162.2
177.6
192.9
160.7
169.9
185.2
200.6
165.3
176.0
192.9
208.2
169.9
182.2
199.0
212.8
SHC
136.3
157.2
172.0
186.9
145.2
164.6
179.5
194.3
153.0
170.6
186.9
201.8
163.9
176.5
192.9
206.2
67
TGC
185.2
188.3
189.8
203.9
186.8
191.4
194.4
197.5
197.5
200.6
205.2
208.2
202.1
205.2
208.2
214.7
SHC
116.2
134.9
163.8
182.9
122.4
143.1
174.5
193.4
128.5
150.0
182.2
203.9
120.5
157.6
194.4
210.3
73
TGC
209.8
212.8
215.9
217.4
215.9
219.0
220.5
222.0
220.5
222.0
223.6
225.1
222.0
223.6
225.1
226.6
SHC
71.0
100.3
129.3
157.6
72.7
105.5
134.6
163.8
76.4
108.6
140.8
173.0
76.4
113.2
143.8
176.0