EasyManuals Logo

Midea MSR1-07HRN1-QB6A User Manual

Midea MSR1-07HRN1-QB6A
63 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #51 background imageLoading...
Page #51 background image
49
T2T1
High speed
TH
DEFROST
Medium speed
TM
DEFROST
Low speed
TL
DEFROST
Breeze/off No need to compare the T2 and T1
(2) After the last defrosting, the time that the outdoor fan is off but the compressor is on in high T2
protection cumulates up to 90 minutes.
Condition of ending defrosting:
If any one of the following items is satisfied, the defrosting will terminate and the machine will turn to
normal heating mode.
(1) The defrosting time is reached to the setting value.
(2) The compressor current reaches or exceeds I
DEFROST
for 7 seconds.
Defrosting action
About the setting defrosting time:
(1) Condition 1 of defrosting;
If case B happens before case A and lasts till case A happens, the setting defrosting time is 10 minutes.
Otherwise the defrosting time is 7.5 minutes.
(2) Condition 2 of defrosting.
The defrosting time is 10 minutes.
(3) No matter what condition of defrosting is, if the defrosting time keeps 7.5 minutes for 3 times, it will
be 10 minutes in the 4
th
defrosting.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Midea MSR1-07HRN1-QB6A and is the answer not in the manual?

Midea MSR1-07HRN1-QB6A Specifications

General IconGeneral
BrandMidea
ModelMSR1-07HRN1-QB6A
CategoryAir Conditioner
LanguageEnglish