run at fan-only mode)
For MSWR1-18CRN1-QB9, MSWR1-21CRN1-QB6 models:
ΔT=T1-Ts Running mode
ΔT>2℃
Cooling
-3≤ΔT≤2℃
Fan-only
ΔT<-3℃
Heating(for cooling only models,
run at fan-only mode)
For MSR1-21CRN1-QB8W, MSR1-21HRN1-QB8W, MSR1-21HRN1-QB4W, MSR1-24CRN1-QB8W ,
MSR1-24HRN1-QB8W,MSR1-24HRN1-QB4W models:
ΔT=T1-Ts Running mode
ΔT>2 ℃
Cooling
-1<ΔT ≤2℃ Fan-only
ΔT≤-1 ℃ Heating(for cooling only models,
run at fan-only mode)
AC will run in auto mode in the below cases:
(1) Press the forced auto button.
(2) If AC is off, it will run in auto mode when timer on function is active.
(3) After setting the mode, AC will run in auto mode if the compressor keeps not running for 15
minutes(20 minutes for MSWR1-18CRN1-QB9 and MSWR1-21CRN1-QB6)
8.4.5 Drying mode
For 7k,9k,12k,16k,17k,18k models:
8.4.5.1 The indoor fan will run following the compressor .If the compressor is on, the indoor fan will run
at low speed .If the compressor is off, the indoor fan will run at breeze.
Running rules: