Light Commercial R410A on-off DM17-01.01.08en
53
5.4. MTB-48HWN1-R / MOU-48HN1-R
COOLING OUTDOORTEMPERATUREDRY
Indoor
Conditions
 21ºC 25ºC 30ºC 35ºC 40ºC 45ºC
21ºCD
15ºCW
TotalcapacitykW
13,02 12,90 12,77 12,52 10,02 9,39
SensitivecapacitykW
10,42 10,32 10,22 10,02 8,01 7,51
InputkW.
14,05 13,96 13,85 13,58 13,98 14,53
24ºCD
17ºCW
TotalcapacitykW
13,31 13,19 13,06 12,80 10,24 9,60
SensitivecapacitykW
10,65 10,55 10,45 10,24 8,19 7,68
InputkW.
5,29 5,25 5,21 5,11 5,26 5,47
27ºCD
19ºCW
TotalcapacitykW
14,63 14,49 14,35
14,07
11,25 10,55
SensitivecapacitykW
11,70 11,59 11,48 11,25 9,00 8,44
InputkW.
5,42 5,39 5,34
5,24
5,40 5,61
32ºCD
23ºCW
TotalcapacitykW
16,39 16,23 16,07 15,76 12,60 11,82
SensitivecapacitykW
13,11 12,98 12,86 12,60 10,08 9,45
InputkW.
6,07 6,03 5,99 5,87 6,04 6,28
HEATING OUTDOORCONDITIONS
Indoor
Conditions

24ºCD
18ºCW
12ºCD
11ºCW
7ºCD
6ºCW
4ºCD
3ºCW
0ºCD
‐1ºCW
‐5ºCD
‐6ºCW
‐7ºCD
‐8ºCW
15ºC
CapacitykW
20,67 20,43
17,89
14,67 12,52 9,84 9,13
InputkW.
5,63 5,57
4,88 4,51 4,40 3,88 3,78
18ºC
CapacitykW
19,74 19,51
17,09
14,01 11,96 9,40 8,71
InputkW.
5,38 5,32
4,66 4,31 4,20 3,71 3,61
20ºC
CapacitykW
18,62 18,41
16,12
13,22 11,28 8,87 8,22
InputkW.
5,08 5,02
4,40 4,07 3,97 3,50 3,41
22ºC
CapacitykW
15,83 15,65
13,70
11,24 9,59 7,54 6,99
InputkW.
4,69 4,63
4,06 3,76 3,66 3,23 3,14
27ºC
CapacitykW
15,83 15,65
13,70
11,24 9,59 7,54 6,99
InputkW.
4,73 4,68
4,10 3,79 3,70 3,26 3,17

Table of Contents