V6-i VRF 50Hz
35
Part 2
-
Outdoor Unit
Engineering Data
Table 2-8.1: MVi-200WV2RN1(A) cooling capacity (continued)
Combination
(%)
(Capacity
index)
Outdoor
temperature
C DB)
Indoor temperature(°C DB/WB)
DB:20.8,WB:14
DB:23.3,WB:16
DB:25.8,WB:18
DB:27,WB:19
DB:28.2,WB:20
DB:30.7,WB:22
DB:32,WB:24
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
50%
-5
6.82
0.63
8.15
0.68
9.45
0.75
10.10
1.03
10.95
1.07
12.45
1.22
13.42
1.32
-2
6.82
0.64
8.15
0.69
9.45
0.77
10.10
1.06
10.95
1.09
12.45
1.24
13.42
1.33
0
6.82
0.64
8.15
0.70
9.45
0.78
10.10
1.06
10.95
1.11
12.45
1.26
13.42
1.36
2
6.82
0.65
8.15
0.71
9.45
0.79
10.10
1.07
10.95
1.13
12.45
1.26
13.42
1.38
4
6.82
0.66
8.15
0.72
9.45
0.80
10.10
1.07
10.95
1.15
12.45
1.30
13.42
1.42
6
6.82
0.67
8.15
0.73
9.45
0.82
10.10
1.08
10.95
1.17
12.45
1.32
13.42
1.46
8
6.82
0.68
8.15
0.75
9.45
0.83
10.10
1.08
10.95
1.18
12.45
1.34
13.42
1.51
10
6.82
0.70
8.15
0.76
9.45
0.85
10.10
1.07
10.95
1.22
12.45
1.37
13.42
1.53
12
6.82
0.71
8.15
0.78
9.45
0.87
10.10
1.08
10.95
1.24
12.45
1.40
13.42
1.55
14
6.82
0.73
8.15
0.80
9.45
0.88
10.10
1.09
10.95
1.26
12.45
1.42
13.42
1.58
16
6.82
0.74
8.15
0.81
9.45
0.90
10.10
1.09
10.95
1.28
12.45
1.44
13.42
1.61
18
6.82
0.75
8.15
0.83
9.45
0.92
10.10
1.09
10.95
1.30
12.45
1.47
13.42
1.64
20
6.82
0.77
8.15
0.86
9.45
0.94
10.10
1.14
10.95
1.33
12.45
1.49
13.42
1.67
21
6.82
0.78
8.15
0.90
9.45
0.95
10.10
1.20
10.95
1.34
12.45
1.51
13.42
1.69
23
6.82
0.83
8.15
0.97
9.45
1.03
10.10
1.28
10.95
1.37
12.45
1.54
13.42
1.72
25
6.82
0.89
8.15
1.04
9.45
1.10
10.10
1.37
10.95
1.41
12.45
1.61
13.42
1.84
27
6.82
0.95
8.15
1.12
9.45
1.18
10.10
1.47
10.95
1.49
12.45
1.72
13.42
1.96
29
6.82
1.02
8.15
1.20
9.45
1.26
10.10
1.52
10.95
1.59
12.45
1.83
13.42
2.09
31
6.82
1.09
8.15
1.29
9.45
1.35
10.10
1.62
10.95
1.69
12.45
1.94
13.42
2.22
33
6.82
1.16
8.15
1.38
9.45
1.44
10.10
1.71
10.95
1.79
12.45
2.07
13.42
2.36
35
6.82
1.24
8.15
1.48
9.45
1.54
10.10
1.76
10.95
1.90
12.45
2.19
13.42
2.51
37
6.82
1.32
8.15
1.59
9.45
1.64
10.10
1.83
10.95
2.01
12.45
2.33
13.42
2.67
39
6.82
1.41
8.15
1.69
9.45
1.75
10.10
1.91
10.95
2.13
12.45
2.47
13.42
2.83
41
6.82
1.46
8.15
1.76
9.45
1.82
10.10
1.97
10.95
2.23
12.45
2.60
13.42
2.97
43
6.82
1.51
8.15
1.80
9.45
1.88
10.10
2.10
10.95
2.28
12.45
2.73
13.42
3.10
45
6.82
1.58
8.15
2.02
9.45
2.15
10.10
2.32
10.95
2.55
12.45
2.99
13.42
3.23
48
6.82
1.86
8.15
2.12
9.45
2.39
10.10
2.65
10.95
2.91
12.45
3.18
13.42
3.44
Abbreviations:
CR: Combination ratio
TC: Total capacity (kW)
PI: Power input (compressor + outdoor fan motor) (kW)
Notes:
1. Shaded cells indicate rating condition.