V6-i VRF 50Hz
55
Part 2
-
Outdoor Unit
Engineering Data
Table 2-8.5: MVi-335WV2RN1(A) cooling capacity (continued)
Combination
(%)
(Capacity
index)
Outdoor
temperature
C DB)
Indoor temperature(°C DB/WB)
DB:20.8,WB:14
DB:23.3,WB:16
DB:25.8,WB:18
DB:27,WB:19
DB:28.2,WB:20
DB:30.7,WB:22
DB:32,WB:24
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
50%
-5
11.42
1.82
13.65
1.98
15.83
2.19
16.92
3.00
18.34
3.11
20.86
3.54
22.48
3.81
-2
11.42
1.85
13.65
2.01
15.83
2.22
16.92
3.07
18.34
3.17
20.86
3.59
22.48
3.87
0
11.42
1.87
13.65
2.03
15.83
2.25
16.92
3.08
18.34
3.20
20.86
3.65
22.48
3.93
2
11.42
1.89
13.65
2.06
15.83
2.28
16.92
3.10
18.34
3.26
20.86
3.66
22.48
4.01
4
11.42
1.91
13.65
2.10
15.83
2.32
16.92
3.10
18.34
3.33
20.86
3.75
22.48
4.11
6
11.42
1.95
13.65
2.13
15.83
2.36
16.92
3.13
18.34
3.39
20.86
3.81
22.48
4.23
8
11.42
1.98
13.65
2.17
15.83
2.42
16.92
3.14
18.34
3.43
20.86
3.87
22.48
4.37
10
11.42
2.02
13.65
2.21
15.83
2.46
16.92
3.11
18.34
3.53
20.86
3.97
22.48
4.43
12
11.42
2.06
13.65
2.26
15.83
2.51
16.92
3.13
18.34
3.60
20.86
4.04
22.48
4.50
14
11.42
2.11
13.65
2.31
15.83
2.56
16.92
3.15
18.34
3.66
20.86
4.11
22.48
4.59
16
11.42
2.15
13.65
2.36
15.83
2.62
16.92
3.15
18.34
3.71
20.86
4.19
22.48
4.66
18
11.42
2.19
13.65
2.41
15.83
2.66
16.92
3.17
18.34
3.78
20.86
4.26
22.48
4.75
20
11.42
2.24
13.65
2.49
15.83
2.72
16.92
3.32
18.34
3.85
20.86
4.33
22.48
4.84
21
11.42
2.26
13.65
2.59
15.83
2.77
16.92
3.49
18.34
3.88
20.86
4.38
22.48
4.89
23
11.42
2.41
13.65
2.80
15.83
2.98
16.92
3.72
18.34
3.96
20.86
4.45
22.48
5.00
25
11.42
2.59
13.65
3.02
15.83
3.19
16.92
3.96
18.34
4.08
20.86
4.68
22.48
5.33
27
11.42
2.76
13.65
3.25
15.83
3.42
16.92
4.27
18.34
4.33
20.86
4.98
22.48
5.69
29
11.42
2.96
13.65
3.49
15.83
3.66
16.92
4.40
18.34
4.61
20.86
5.30
22.48
6.06
31
11.42
3.16
13.65
3.74
15.83
3.91
16.92
4.69
18.34
4.89
20.86
5.63
22.48
6.45
33
11.42
3.37
13.65
4.01
15.83
4.18
16.92
4.94
18.34
5.19
20.86
5.99
22.48
6.85
35
11.42
3.59
13.65
4.29
15.83
4.46
16.92
5.09
18.34
5.49
20.86
6.36
22.48
7.28
37
11.42
3.83
13.65
4.60
15.83
4.76
16.92
5.32
18.34
5.83
20.86
6.75
22.48
7.73
39
11.42
4.08
13.65
4.91
15.83
5.07
16.92
5.52
18.34
6.18
20.86
7.15
22.48
8.21
41
11.42
4.23
13.65
5.10
15.83
5.26
16.92
5.72
18.34
6.45
20.86
7.53
22.48
8.59
43
11.42
4.38
13.65
5.20
15.83
5.45
16.92
6.10
18.34
6.61
20.86
7.91
22.48
8.97
45
11.42
4.59
13.65
5.86
15.83
6.24
16.92
6.73
18.34
7.39
20.86
8.68
22.48
9.36
48
11.42
5.39
13.65
6.15
15.83
6.92
16.92
7.68
18.34
8.44
20.86
9.21
22.48
9.97
Abbreviations:
CR: Combination ratio
TC: Total capacity (kW)
PI: Power input (compressor + outdoor fan motor) (kW)
Notes:
1. Shaded cells indicate rating condition.