82
CVA 265x & CVA 266x
Option Setting Description Standard Setting
Maintenance
Carry out
Perform capsule cage
replacement; see
Section 060-4.2.
-
Showroom
prog.
Demo program
The appliance can be
operated but does not
heat up.
Off
Off
The demo program is
deactivated.
Factory default
All settings
All settings adjusted
within programming
mode will be reset
(the language setting
remains unchanged).
The demo program, if
set, remains
activated.
-
User profiles
All user profiles are
deleted.
Table 060-5: Customer Programming, CVA 2652/2662
1
If the language is set incorrectly, search for the flag symbol to enter the language
setting area.
Water Hardness
Setting
Water Hardness
Max. Flow Quantities until
Descale is Displayed
Grains per
Gallon
Parts per
Million
Steam
Coffee/Hot
Water
1 - Soft 0 to 7 0 to 125 92 oz. 4058 oz.
2 - Medium 8 to 14 143 to 250 69 oz. 3043 oz.
3 - Hard 15 to 21 268 to 375 46 oz. 2029 oz.
4 - Very Hard > 21 >375 23 oz. 1353 oz.
Table 060-6: Water Hardness Settings
4.2 Capsule Cage Replacement
After approximately 15,000 coffees have been served, the capsule cage in
the brew unit must be replaced (see the operating instructions).
1. Access the programming mode as outlined in Section 060-4.1.1 or 060-4.1.2.
2. Turn the right switch knob or press the < or > touchpads until
MAINTENANCE is displayed.
3. Press the right switch knob or the OK touchpad.
4. Turn the right switch knob or press the < or > touchpads until Carry out is
displayed.
5. Press the right switch knob or the OK touchpad to carry out the service task.
6. The brew unit transports the capsule cage downwards.
7. Open the door.
8. Remove the capsule plate.
9. Remove the seal downwards.
10. Unscrew the capsule cage using the service tool.
11. Install a new capsule cage using the service tool.
12. Install the seal from underneath.
13. Slide in the capsule plate.
14. Close the door. The brew unit will move the capsule cage upwards. The
appliance can be operated again normally.

Table of Contents

Other manuals for Miele CVA 2650

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Miele CVA 2650 and is the answer not in the manual?

Miele CVA 2650 Specifications

General IconGeneral
BrandMiele
ModelCVA 2650
CategoryCoffee Maker
LanguageEnglish

Related product manuals