EasyManua.ls Logo

Miele CVA 5065 - Message Fault - 73 appears

Miele CVA 5065
84 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
. . . the message "Fault - 73" appears
in the display.
The brew unit cannot be positioned
correctly.
^
Take the brew unit out of the machine
and clean it thoroughly (see
"Cleaning and care - Brew unit").
^ Push the coffee ejector on the brew
unit into the correct position.
^ Set the brew unit to one side and
replace the waste container and the
water container in the machine.
^
Close the door.
The brew unit motor will now move
into the correct position.
^
When "Fit the brew unit" appears,
open the door and replace all the
parts in the machine.
^
Close the door.
If the fault message continues to
appear in the display, please call the
Miele Service department, quoting the
fault code.
. . . the message "Fault - 74" or "Fault
- 77" appears in the display.
^
Switch the machine off and then back
on again.
If the fault message appears in the
display again, contact the Miele Service
Department.
. . . the message "Check the brew
unit" appears in the display.
The brew unit may be dirty.
^
Follow the instructions in the display.
^ Clean the brew unit (see "Cleaning
and care - Brew unit").
^ Set a medium grinder setting and a
medium amount of coffee (see
"Setting the coffee grinder" and
"Settings: customising your machine -
Setting the amount of coffee"). Set the
amount of coffee to medium in any
User profiles as well.
. . . the ground coffee chute cover
cannot be pushed in properly.
^
Is the lid of the ground coffee chute
closed?
. . . You can hear "gurgling" or
"rushing water" noises.
^
The water container is being filled
automatically with water.
Problem solving guide