Important
The wires in the mains lead are col-
oured in accordance with the following
code:
Green/yellow = earth
Blue = neutral
Brown = live
If the appliance is to be connected via
a plug and socket, please note the fol-
lowing:
As the colours of the wires in the mains
lead of this appliance may not corre-
spond with the coloured markings
identifying the terminals in your plug,
proceed as follows:
The wire which is coloured green
and yellow must be connected to the
terminal in the plug which is marked
with the letter E or by the earth sym-
bol z or coloured green or green
and yellow.
The wire which is coloured blue must
be connected to the terminal which
is marked with the letter N or col-
oured black.
For U.K., IRL, ZA: The wire which is
coloured brown must be connected
to the terminal which is marked with
the letter L or coloured red.
For Australia / New Zealand: The
wire which is coloured brown must
be connected to the terminal which
is marked with the letter A or col-
oured red.
WARNING:
THIS APPLIANCE MUST BE
EARTHED
Electrical connection
37