EasyManua.ls Logo

Miele WS 5425 MC 13 - UK Electrical Connection Details

Miele WS 5425 MC 13
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electrical connection U.K.
All electrical work must be carried out
by a suitably qualified and competent
person, in strict accordance with na
-
tional and local safety regulations.
Ensure power is not supplied to the ma
-
chine while installation work is being
carried out.
The voltage, rated load and fuse rating
are given on the data plate. Please en
-
sure these match the site mains supply.
This washer-extractor is supplied as
standard for connection to either:
– 230 - 240 V / 1N / 50 Hz
13 A fuse rating
with a cable and plug for connection
to a suitable switched socket.
or
– 230 - 240 V / 1 N / 50 Hz,
30 A fuse rating
single phase supply for connection
to a suitable isolator.
or:
–
400 V / 2 phase + N / 50 Hz
2 x 15 A fuse rating
for connection to a suitable isolator.
or:
–
for off-shore use, WSE 5425
for connection to a suitable isolator.
The machine is not convertible.
Connection of single and two
phase machines:
–
230 - 240 V / 1 N / 50 Hz
(30 amp fuse rating U.K.)
–
400 V / 2 phase + N / 50 Hz
(2 x 15 amp fuse rating U.K.)
Connection should be made via a suit
-
able isolator which complies with na
-
tional and local safety regulations, and
the on/off switch should be easily ac
-
cessible for servicing work.
For extra safety it is advisable to install
a residual current device (RCD) with a
trip current of 30 mA (in accordance
with DIN VDE 0664, VDE 0100 Section
739).
When switched off there must be an
all-pole contact gap of 3 mm in the iso-
lator switch (including switch, fuses and
relays acc. to VDE 0660).
Important
For 400 V 2 phase connection, the ma
-
chine is supplied with a 4-core cable in
the following colours:
Black = live
Brown = live
Blue = neutral
Green and yellow = earth.
If a 3 phase supply is provided on site,
then one of the phases is not used.
WARNING
THIS APPLIANCE MUST
BE EARTHED
Installation
44

Table of Contents