    samuellawsonAug 11, 2025
    Why is my Migali C-F40-NG producing yellow flame and black smoke?
    • A
      Anita RayAug 11, 2025
      Yellow flame and black smoke from your Migali Fryer can occur due to several reasons: using the wrong type of gas, a mismatch between the nozzle aperture and gas resources, insufficient air for ignition, or heavy gas sources during peak usage. To resolve this, try changing the gas, adjusting the nozzle diameter, increasing the damper opening degree, or reducing the valve flow during peak hours and increasing it afterward.
  • S
    Stephen ThomasAug 21, 2025
    What to do if my Migali C-F40-NG ignites the pilot light but not the main fire?
    • R
      Randy SandersAug 21, 2025
      If your Migali Fryer ignites the pilot light but not the main fire, it could be due to several reasons. It might be caused by insufficient gas pressure in the pipe, occlusion of the main fire nozzle, problems with the gas control valves, excessive distance between the pilot light and the main fire, or a pilot light flame that is too low. To address this, contact the local gas supply department, dredge the nozzle, change the gas control valves, adjust the distance between the pilot light and the main fire, or adjust the height of the pilot light.
  • S
    Scott CohenAug 31, 2025
    What to do if I close gas and hear a sound of fire in my Migali C-F40-NG?
    • D
      Daniel OwensSep 1, 2025
      If you hear a sound of fire after closing the gas in your Migali Fryer, possible causes include insufficient gas pressure in the pipe, a mismatch between the nozzle aperture and gas resources, insufficient flow in the connection pipe, or a damper opening degree that is too large. You should contact the local gas supply department, adjust the nozzle diameter, increase the pipe’s allowable flow, or adjust the damper.