IBUKI Air Enhancer
User Manual
MODEL NO: MA-01
SHOPMIKO.COM
Question and Answer IconNeed help?

Do you have a question about the MIKO IBUKI MA-01 and is the answer not in the manual?

Overview

The Miko IBUKI Air Enhancer, model MA-01, is a desktop air purifier designed to improve indoor air quality. This user manual provides comprehensive instructions for its operation, maintenance, and troubleshooting.

Function Description:

The IBUKI Air Enhancer functions primarily as an air purifier, utilizing a multi-stage filtration system to remove airborne particles and odors. It also incorporates an aromatherapy module, allowing users to diffuse essential oils for a more pleasant environment. The device features a touch panel for intuitive control, offering various settings for fan speed and a timer function.

Important Technical Specifications:

While specific technical specifications like CADR (Clean Air Delivery Rate) or power consumption are not detailed in the provided pages, the device operates on a standard voltage of 110V 60Hz. It uses a replaceable filter, which is crucial for its purifying function. The aromatherapy module uses an aromatherapy block where essential oils can be dripped.

Usage Features:

  • Easy Setup: The manual outlines a straightforward setup process, including filter installation and aromatherapy box placement. Users need to remove the plastic bag from the filter before use.
  • Touch Button Operation: The device is controlled via a touch panel with several buttons:
    • Power Button: Tapping the power button turns the machine on, defaulting to low-level operation. Pressing and holding for 2 seconds puts it into standby mode.
    • Wind Speed Gear Button: Allows users to cycle through low, medium, and high fan speeds.
    • Timer Switch: Sets the device to turn off automatically after 4 or 8 hours. The indicator light twinkles for 4 hours and stays on for 8 hours. Tapping again cancels the timer.
    • Filter Reset Switch: Used to reset the filter replacement reminder after a new filter has been installed.
  • Aromatherapy Module: The aromatherapy box is pre-installed. Users can remove it, drip essential oil onto the aromatherapy block, and reinsert it to diffuse scents with the airflow.
  • Safety Precautions: The manual emphasizes several safety guidelines, including:
    • Do not use the device beyond the rated voltage (110V 60Hz).
    • Avoid arbitrarily processing, bending, drawing, twisting, or bundling the power line.
    • Keep the power line away from high-temperature objects.
    • Do not place heavy objects on the power line.
    • Do not use if the power line or plug is worn or loose.
    • Avoid inserting or pulling the power line with wet hands.
    • Do not change the power line without permission.
    • Regularly clean dust from the power plug and socket.
    • Do not use solvent-based desktop air purifiers such as alcohol or thinner.
    • Do not place the desktop air purifier in a place where flammable gas is easily leaked or in a flammable, explosive, or corrosive atmosphere.
    • Do not pull on the power cord while moving or storing.
    • Do not touch the power cord plug with wet hands.
    • Supervise children to avoid direct operation or contact with desktop air purifiers.
    • Do not put fingers or metal objects in the gaps between the air inlet and outlet.
    • Do not allow volatile substances or combustible materials like cigarettes to float into the unit.
    • Ensure there is an electric control board on the base, away from water.
    • The air intake is located on the base of the unit, and the air outlet is at the top. Do not block or obstruct the air intake or outlet.
    • Do not use the power cord or plug if it is damaged.
    • Regularly check and replace the filter. If the filter is blocked, the air will be ineffective, and power consumption will increase.
    • When not in use for a long time, turn off the power and avoid exposure to sunlight.
    • When moving or performing maintenance, be sure to stop operation and unplug the power cord.
    • If the machine fails, stop using it and turn off the power. Contact after-sales personnel for inspection.
  • Troubleshooting: A dedicated section helps users diagnose common issues such as the machine not working, peculiar smell from the air outlet, bad performance, or no air blowing out, providing possible solutions.

Maintenance Features:

  • Regular Cleaning: For best results and long unit life, regular preventative maintenance is recommended. The main body should be cleaned once a month using a soft cloth dampened with warm wet cloth or neutral detergent. Avoid using hot water (higher than 40°C) or strong alkaline/acidic detergents.
  • Filter Replacement: The filter is a consumable item and should be changed every three months. New filters can be purchased from shopmiko.com. The filter replacement process involves:
    1. Disassembling the filter cover at the bottom of the air intake.
    2. Removing the old filter (which comes in a PE bag).
    3. Taking the new filter out of its plastic bag.
    4. Installing the new filter.
    5. Closing the filter cover.
    6. Plugging in the power cord and turning on the machine.
    7. Pressing and holding the FILTER RESET button for 2 seconds until the buzzer sounds and the indicator light goes out.
  • Storage: When storing the device, pull out the power cord, cover the machine with a plastic bag, and place it in a dry place for safekeeping. Do not store the product upside down, which may lead to product failure.
  • Warning: Non-authorized personnel should not dismantle the machine. Always unplug the power plug when changing or cleaning the filter set. If troubleshooting methods in the manual do not resolve a failure, contact the support center.