17
Problem Possible Cause Solution
High Total Dissolved Solids (TDS) 
in the Product Water
(continued)
The Product Water and Drain Water
lines are reversed.
Correct plumbing.
No drain ow, Drain Restrictor is
clogged.
Clear or replace Drain Restrictor.
No drain ow, the drain orice in
the Dispensing Faucet is plugged.
Clear or replace Dispensing Faucet.
The ASO Valve is not closing. Repair or replace the ASO Valve
Components
New In-Line or Activated Carbon
Post Filter not rinsed completely.
Flush with several full tanks of
Product Water.
The Feed Water TDS has increased. An increase in Feed Water TDS will
give a corresponding increase in
Product Water TDS.
Tastes and odors in the Product 
Water
The In-Line or Activated Carbon
Post Filter is exhausted.
Replace Filters.
There is foreign matter in the Holding
Tank.
Clean, ush and sanitize the system.
Replace the lters.
The Product Water and Drain Water
lines are reversed.
Correct plumbing.
Dissolved gasses in the Feed Water. Pretreat Feed Water to remove
dissolved gasses.
Increase in Product Water TDS. See high TDS in the Product Water
section.
Drain Water overows at the 
Dispensing Faucet
Air Gap is blocked. Clear Air Gap.
Rinse with vinegar for removal of
calcium buildup.
Drain tubing is clogged. Clear tubing.
Drain Clamp hole is misaligned. Align with hole in the drain pipe.
Excessive drain ow rate. Replace Drain Restrictor.
Faucet leaks or drips Leaks from base of the delivery
tube.
O–ring is bad, replace O–ring.
Amber light on Water Quality 
Monitor
System not being used for extended
period of time
Empty storage tank. Wait 15 minutes
(the system is making water) and test
water quality again.
Filters are plugged or membrane is
fouled or exhausted.
Replace lters and/or membrane.
Fitting leaks in general Close the Feed Water Saddle Valve and relieve pressure before
disconnecting any tubing or replacing any tting. Before replacing a tting,
re–cut the tubing and re–insert into the tting to see if that solves the leak. If
pipe threads are leaking, remove and retape with Teon tape.