EasyManua.ls Logo

Minebea CSD-891B - Page 147

Default Icon
230 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
133
9−1−6. Scaling of analog output
The analog output for standard specifications is set between the minimum value and the
maximum value with the output of 0 to 2 000.
By changing the F−21 and F−22 , optional value can be decided.
0 display
The minimum
value
The maximum
display
+110 % of the
maximum display
Approx.2.4 mA
Approx.−11 V
Approx.21.6 mA
Approx.11 V
The maximum
value
Analog output
Display
20 mA
10 V
0V
−10 % of the
maximum display
4mA
F−21 sets the display when the minimum value is desired to output.
F−20 sets the display when the maximum value is desired to output.
例)F−21:Set as 1 000
F−22:Set as 5 000
When the display is 5 000, the maximum value outputs.
When the display is 1 000, the minimum value outputs.
1 000
5 000
5 500
20 mA
10 V
4mA
0V
The minimum value
Approx.2.4 mA
Approx.−11 V
Approx.21.6 mA
Approx.11 V
The maximum value
Analog output
Display
Warning ● Take care that the setting on the F−22 doesn’t exceed the maximum
display value that has set in the Chapter 5.
● For the F−21, less value than the value to set for F−22 should be set.
If neglected, the correct output can’t be obtained.