150
(2) Command mode
1
Reading out the load data(Host→CSD−891B)
Command No.
Operation
20 Reading out the display
interlocked data
21 Reading out Gross weight data
22 Reading out Net weight data
23 Reading out A/Z cancel data
Return(CSD−891B→Host)
2 4 6 8 10 12 14
@ 0 0 2 2 Terminator
Load data
Sign of load data
Command No.
D The load data enters from the right end.
D When the data is minus, “−” sign and when plus, “+” sign is added.
D Load weighing data performs zero suppress.
D In case that the decimal point is set with the F−56, and at the same time the
decimal point is specified with the F−01, it will be added to the specified
position.
D The message will be output at the time of overloaded.
D The empty sections are all spaces.
2 4 6 8 10 12 14
@ 0 0 2 2 − 1 2 3 Terminator
2 4 6 8 10 12 14
@ 0 0 2 2 + 0 . 1 2 3 Terminator
2 4 6 8 10 12 14
@ 0 0 2 2 + O L Terminator
2 4 6 8 10 12 14
@ 0 0 2 2 − O L Terminator
2
Reading out comparative data (Host→CSD−891B)
Command No.
Operation
30 Reading out S0 data
31 Reading out S1 data
32 Reading out S2 data
33 Reading out S3 data
34 Reading out S4 data
246
@ 0 0 2 2 Terminator
Command No.
246
@ 0 0 3 0 Terminator
Command No.