64
Procedures
Transmit the change command of the maximum
display value from the host, and set the
maximum display value.
The range of the maximum display value is (the
minimum digits×100)〜99 999.
To make the performance effectively, set the
value in the range as follows. If you set the value
exceeding the following ranges, there may cause
the unstable displays, etc.,
The maximum
display value
2 4 6 8 10 12 14
@ 0 0 1 1 2 0 0 0 Termi
ID No.
Command Host→CSD−891B
R
eturn
C
SD
−
891B
→
Host
-nator
3
The setting range of the
maximum display value
100〜10 000
200〜20 000
500〜50 000
1 000〜99 990
The minimum
digits
1
2
5
10
The display in the load display section displays
“−RS−” and “LOAD” alternately.
Don’t attach the decimal point to the
setting value in the command data.
The setting value in the command data is
put from the right, and an unnecessary
space is given as space.
2 4 6 8 10 12 14
@ 0 0 1 1 0 2 0 0 0 Termi
ID No.
R
eturn
C
SD
−
891B
→
Host
・Normal termination
The maximum
display value
2 4 6 8 10 12 14
@ 0 0 1 1 E R - 2 Termi
ID No.
・Set in error
-nator
-nator