EasyManua.ls Logo

Minibar Systems Primo 30 - To re-mount the silent cooler; To change heater element

Minibar Systems Primo 30
15 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PRIMO TECHNICAL MANUAL Page
7
3
To change silent chiller (continued)
To re-mount the silent cooler:
14. Check that there is thermal mastic remaining in the bar aperture to create a
thermal joint.
15. Re-mount the chiller to the cold cube – ensure evaporator tube is fully inserted
into the thermal mastic and aluminium extrusion plate
16. Re-fix top 4 screws into the condenser fin supports.
17. Re-fix lower support screw. Take care to re-fix the earth cable
18. Re-connect heater wires, 2 Faston, to junction box terminals
19. Re-fix junction box, take care with position of cables
20. Secure insulation sleeve to lower part of chiller with cable tie
21. Re-connect power lead and test.
4
To change heater element
Proceed as per Chapter 3, steps 1 - 6
1. Using a test meter check the resistance across the terminals
2. If open circuit proceed to change heater element as follows:
i. Cut 3 cable ties securing boiler insulation sleeve
ii. Using a screwdriver, carefully insert in joint of 2 sections of plastic
housing, at the same time squeeze the area adjacent to the joint.
iii. Remove the 2 sections of the plastic cover.
continued …