Short instruction
MINIMAX GmbH & Co. KG Industriestrasse 10/12 23840 Bad Oldesloe Germany FHK34, 908143 1 / 10
Form No. F_102011
AMX5000
Aspirating smoke detector
From production number 060608 and SW version 01.02.01
The AMX5000 aspirating smoke detector performs the task of
taking continuous air samples via one or two sampling pipe net-
works from a monitored area and feeding the samples to one
or two smoke sensors.
The AMX5000 consists of the detector housing and one or two
sampling pipe tube networks. The sampling pipes have several
sampling holes whose size is such that each hole draws the
same amount of air. The sampling pipes may be I-, U-, T-, H-,
or E-shaped. The sampling pipes are usually symmetrically de-
signed. Asymmetrical sampling pipe tube networkscan also be
implemented using the “HELIOS PipeCalc” calculation soft-
ware.
Description
You find all necessary Information for setting up
AMX5000 fire alarm systems in the short instruction;
for the complete information and specifications refer t
o
th
e Technical Description AMX5000, FHB 34 (908146)
Integrated in the detector housing is a high-speed fan which, in
conjunction with the sampling pipe, ensures uninterrupted air
supply to the detector housing. Airflow monitoring detects any
block-ages or breaks in each of the sampling pipe networks.
The AMX5000 is available in four versions:
AMX5001 for 1 sampling tube, and 1 smoke sensor
without smoke level indicator;
AMX5002 for 2 sampling tubes, and 2 smoke sensors
without smoke level indicator;
AMX5101 for 1 sampling tub
e, and 1 smoke sens
or
with smoke level indicator;
AMX5102 for 2 sampling tubes, and 2 smoke sensors
with smoke level indicator.
The AMX5000 can be equipped with the following smoke sen-
sor types:
OMX5005 Sensitivity range 0.5%/m to 10%/m
(0.15%/ft to 3.15%/ft)
OMX5010 Sensitivity range 0.1%/m to 10%/m
(0.03%/ft to 3.15%/ft)
OMX5020 Sensitivity range 0.02%/m to 10%/m
(0.006%/ft to 3.15%/ft)
The AMX5000 aspirating smoke detector has four slots for ex-
pansion modules. The following modules can be added:
KMX5005 RK Relay Interface Module with 5 relays (max.
2 units);
MMX5005 Memory module
Other In preparation (interface module)
The AMX5000 can be linked to a higher level FACP by means
of relays.
The AMX5000 can be connected to a fire alarm system by
using potential free contacts.
Integration in the System FMZ5000 Loop Ap is possible by mo-
dules. Displaying status and control of the AMX device can
thus be performed directly from the FACP.
Fig. 1 AMX5102
A further expansion option is the KMX5005 RK Relay Interface
Module. This module enables the availability of all three pre-si-
gnal levels as well as the states “smoke sensor dirty” and “LS-
Ü blockage” as relay contacts. The relays are also freely confi-
gurable via the HELIOS Config configuration software.
The MMX5005 Memory module serves to record operating data
.
The AMX5000 aspirating smoke detector can be used for:
Equipment monitoring:
EDP systems, electrical distributors,
switch cabinets, etc.
Space surveillance:
EDP rooms, clean rooms, warehouses,
high-rack storage buildings, hollow floors, protection of cul-
tural objects, transformer stations, prison cells, etc.
The AMX5000 is also deployed in areas where conventional
point type detectors are used. The local provisions and regula-
tions must be observed from case to case.
The response behavior of the AMX5000 has been tested in
compliance with EN 54-20, Class A, B and C (or NFPA 72).
When setting up AMX5000 fire alarm systems, the in-
formation and specifications in “Technical Descripti-
on AMX5000” must be observed and adhered to.
This includes among others:
General
Section 1
Planning Section 4
Mounting Section 5
Installation Section 6
Commissioning Section 7
Opening the detector housing
Press the rotary snap locks firmly with the screwdri-
ver (min. No. 5) toward the housing base and then
turn 90°. The position of the lock slit shows the cur-
rent state:
approx. 45° angled toward detector housing corne
r
= closed
approx. 45° angled toward detector housing edge
= open
The rotary snap locks must snap into place.
The housing cover (control unit) is connected to the Main Board
by a flat cable. Make sure that when the housing cover is lifted
away the flat cable does not become damaged.
Question and Answer IconNeed help?

Do you have a question about the MiniMax AMX5000 Series and is the answer not in the manual?

MiniMax AMX5000 Series Specifications

General IconGeneral
Power Source120V AC
Battery Backup9V Battery
Alarm Sound Level85 dB at 10 feet
Interconnect CapabilityYes
Weight0.5 lbs
ComplianceUL 217
Operating Temperature40°F to 100°F (4°C to 38°C)
Humidity Range10% to 95% relative humidity (non-condensing)

Summary

AMX5000 Aspirating Smoke Detector Overview

AMX5000 Detector Description

Provides an overview of the AMX5000 aspirating smoke detector and its basic functionality.

Opening the Detector Housing

Instructions on how to safely open the AMX5000 detector housing for access.

AMX5000 Connections and Configuration

AMX5000 Connection and Wiring

Details electrical connections, main board interfaces, KMX5005 RK terminals, and wiring principles.

Deploying Smoke Sensors

Provides instructions and precautions for installing smoke sensors into the detector housing.

AMX5000 Displays and Programming

Control and Main Board Displays

Explains the LED indicators on the control unit and the segment display on the Main Board.

AMX5000 Programming and Switch Settings

Details switch settings and parameters for configuring the AMX5000 system.

AMX5000 Planning and System Limits

System Limits and Planning

Covers system limits for planning without PipeCalc, including normative and non-normative specifications.

System Limits Table (No PipeCalc)

Table detailing system limits for EN 54-20 compliance (Class A, B, C) without PipeCalc software.

AMX5000 Sampling Hole Details

Sampling Hole Planning (No PipeCalc)

Provides tables for sampling hole diameters for various pipe shapes without PipeCalc.

I, U/T, H/E-Shaped Sampling Pipes

Hole diameters for different sampling pipe shapes based on hole number and pipe branch.

AMX5000 Configuration Options

Configuration Options (Table A)

Detailed configuration settings for smoke sensors and day/night control, saved to switch settings X01-X03.

Configuration Options (Table B)

Configuration settings for the entire AMX5000, including autolearning, day/night control, and general faults.

AMX5000 Advanced Configuration

Configuration Options (Table C)

Independent configurations for time, relay/OC outputs, and reset buttons, assignable to switch settings.

Relay Allocation Configuration

Options for allocating criteria to relays for smoke sensor I/II and general fault signals.

AMX5000 Commissioning and Operation

Commissioning and Starting Up

Procedures for initial reset, data collection, airflow monitoring adjustment, and initial power-on.

Re-programming and Initial Reset

Instructions for reprogramming switch settings and performing an initial reset on the AMX5000.

Measurements and Commissioning Protocol

Guidelines for performing measurements and filling out the commissioning protocol for the AMX5000.

AMX5000 Testing and Specifications

Checking Fault and Alarm Actuation

Tests for verifying airflow monitoring and alarm actuation functionality.

Article Numbers and Spare Parts

Lists article numbers for the AMX5000 detector, accessories, and software.

AMX5000 Dimensional Drawing

Provides a detailed dimensional drawing of the AMX5000 detector housing.

AMX5000 Technical Data

AMX5000 Technical Data

Presents comprehensive technical specifications for the AMX5000 aspirating smoke detector.

Related product manuals