47
6]
Adjustment
of
R3
—Adjustment
of
meter
pointer
MMeasuring
instruments:
>
081
standard
circuit
tester
‘Model
SC
1)
or
constant-voltage
DC
power
source
(Model
E-1
or
E-2)
:
Brightness
box
‘Model
L.
222
or
L-223
>
Power
source
adapter
{081-4204-79)
:
Standard
lens
50mm
i
1.4)
:
Temporary
cover
for
brightness
calibration
[081-1031-79)
:
Serew-driver
for
brightness
calibration
WStandard
value:
(1)
Brightness
:Ev
11
ASA
100
(BV
6)
ASA
sensitivity
:100
(SV
5)
Diaphragm
aperture:
F
11
(AV
7)
(2)
Brightness
:Ev
15,
ASA
100
(BV
10)
ASA
sensitivity
:100
(SV
5)
Diaphragm
aperture:
F
5.6
(AV
5)
HM
Adjustment
procedures:
Pointer
position
Pointer
position
1.
Set
the
measuring
apparatus
as
shown
in
the
figure
below
and
set the
power
source
voltage
at
3.
0V.
Digital
time
counter
POWER:
OFF
na
ml
mu
=r
Screw-driver
for
brightness
calibration
Fal
RB
5
Brightness
box
mF
Temporary
cover
for
brightness
calibration
fe)
re)
OF
8
Standard
lens
081
standard
circuit
tester
Power
source
adapter
2.
Set
the
body
PV
button
depressed
(PV
SW:ON)
and
the
standard
lens
at.
3.
With
the
brightness
box:
Ev
11
(ASA
100)
and
the
standard
lens:
F
11,
look
in
the
finder
and
make
adjustment
by
means
of
Rs
so
that
the
meter
pointer
be
in
the
position
for
standard
value
(1).
The
pointer
moves
up
if
R3
is
turned
right
and
moves
down
if
R3
is
turned
left.
4.
With
the
brightness
box:
Ev
15
(ASA
100)
and
standard
lens:
F
5.6,
look
in
the
finder
and
check
to
see
that
the
meter
pointer
is
within
the
range
of
standard
value
[2).
5.
If
the
meter
pointer
is
not
within
the
range
of
standard
value
(2)
when
Ev
15
(ASA
100)
is
set,
make
adjustment
by
parting
with
Ev
11
(ASA
100),