1.
How
to
Confirm
Manual
Time
M@iMeasuring
Instruments
:081
Standard
Circuit
Tester
(Model
SC-]I)
:
Digital
Time
Counter
(Model
TC-1)
:
Shutter
Tester
W@Standard
Value
Set
Position
of
“SS
SEL”
of|
_Indication
of
Shutter
Tester
—_|
eR
Time
081
Standard
Circuit
Tester
|
Standard
Figure
Allowed
Figure
1/1
|
1000ms
758
~
1320ms
(+0.4Ev)
1
sec.
1/4
___-250ms
189~330ms
(+0.
4Ev)
251ms
1/1000
0.98ms
0.563~1.71ms
(+0.
8Ev)
2
ms
Hi
How
to
Confirm
1.
Unsolder
the
lead
wires
of
SW4(+side)
and
Mg
(+and—sides)
of
circuit
base
plate
plate
B
(0602)
and
set
them
to
the
tester
as
shown
in
the
follwing
diagram.
@
Digital
Time
Counter
e
Shutter
Tester
SEP-COM
SW:
SP Curtain
Running
Direction:
DOWN
FUNCTION
:
EXP-T
Trigger
Level
A-CH:
+1
(V)
B-CH:
+1
[(V)
Trigger
Slope
A-CH!+
#081
Standard
Circuit
Tester
SS
SEL:
1,
1/4,
1/1000
BCH:
+
V
SEL:3.0V
ay
Body
Earth
Digital
Time
Counter
SW4(+)
081
Standard
Circuit
Tester
Shutter
Tester
2
.Select
a
shutter
speed
by
the
“SS
SEL”
dial
of
the
081
standard
circuit
tester.
Press
the
“RESET”
SW
of
the 081
standard
circuit tester,
release
the
shutter,
and
Confirm
that
the
measured
figure
of
1/1,
1/4
and
1/1000
remains
within
the
range
of
the
rated
figures.
3
.If
the
measured
figures
of
1/1,
1/4
and
1/1000
don’t
remain
within
the
range
of
the
rated
figures,
check
the
shutter
block.

Related product manuals