EasyManua.ls Logo

Mipro MA-708 - Page 46

Mipro MA-708
66 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MA-708(AMP) TEST AND ALIGNMENT INSTRUCTIONS
NO
MEASUREMENT
ADJUSTMENT
SIGNAL INPUT
PREPARATION
UNIT SETTING
TESTPOINT ADJUSTER
NORMAL
VALUE
2 Output power
AF:1KHZ/-10.2dB
DC Power:
32V,12V/6A
Audio Analyzer
power meter
P4
DIST=8-10.5%
POWER ≧
130W
3
100HZ
FREQUENCY
RESPONSE
AF:100HZ/-12.2dB
DC Power:
32V/12V/6A
Audio Analyzer
power meter
P4
POWER
100W±10W
4
20KHZ
FREQUENCY
RESPONSE
AF:20KHZ/-12.2dB
DC Power:
32V/12V/6A
Audio Analyzer
power meter
P4
POWER
105W±10W
5
T.H.D
DC Power:
32V/12V/6A
AF:1KHz/-23dBV
Audio Analyzer
DIST meter
P4
≦1%
6 S/N
DC Power:
32V/12V/6A
AF:1KHz/-3.8dBV
Audio Analyzer
DIST meter
P4
≧95
7 Dynamic Current
DC Power:
32V/12V/6A
AF:1KHz/-12.2dBV
DC meter
3.7A±0.2A
A708R03B
SERVICE / TECHNICAL MANUALS

Other manuals for Mipro MA-708

Related product manuals