LB0261 Rev A 01/2018 © Miramar Labs, Inc. 2018, Confidential Information of Miramar Labs, Inc. Page 1
MD4000-MC
User Manual
Question and Answer IconNeed help?

Do you have a question about the Miramar Miradry MD4000-MC and is the answer not in the manual?

Miramar Miradry MD4000-MC Specifications

General IconGeneral
ModelMD4000-MC
TechnologyMicrowave energy
ManufacturerMiramar Labs
ApplicationTreatment of excessive underarm sweating (hyperhidrosis)
Treatment AreaUnderarms
PrecisionTargeted delivery of microwave energy to sweat glands
FDA ApprovalFDA-cleared
Treatment DurationApproximately 1 hour per session
Number of TreatmentsTypically 1-2 treatments
Recovery TimeMinimal downtime, usually a few days
Side EffectsTemporary swelling, tenderness, and numbness in the treated area

Summary

MiraDry MD4000-MC User Manual

Contact and Representative Information

Manufacturer Details

Information about Miramar Labs, Inc., the manufacturer of the miraDry System.

European Authorized Representative

Details for MedPass International Ltd., the authorized representative in Europe.

System Symbols and Icons

Device and Packaging Symbols

Explanation of symbols used on the miraDry device and its packaging.

Touchscreen GUI Icons

Explanation of icons displayed on the miraDry System's Touchscreen Graphical User Interface.

MiraDry System Overview

MiraDry System Components

Overview of the main components of the miraDry System, including console and handpiece.

Console Connections and Control Features

Details on miraDry Console connections, ports, and control features for system operation.

Indications for Use

Contraindications

Potential Risks

Clinical Data Overview

Randomized, Blinded, Multicenter Study

Summary of a clinical study involving the miraDry System, detailing design, subjects, and results.

Clinical Study Results

Single Group Commercial Device Study

Details of a study using the miraDry System, focusing on efficacy and patient satisfaction.

Efficacy and Patient Satisfaction Data

Commercial Device Study Efficacy

Presents efficacy measures like hair count reduction, patient satisfaction, and odor self-assessment.

Safety Warnings and Precautions

Setup and Environmental Precautions

Safety guidelines for setting up and operating the miraDry System in specific environmental conditions.

Equipment Usage Safety

Equipment Use Warnings

Critical warnings and precautions for the safe operation and handling of miraDry System equipment.

Clinical Safety Guidelines

Clinical Warnings and Precautions

Precautions related to patient selection, treatment, and anesthesia for the miraDry System.

Cleaning and Maintenance Safety

Cleaning Warnings and Precautions

Safety guidelines for cleaning the miraDry Console and its components.

Maintenance Warnings and Precautions

Precautions to follow when performing maintenance on the miraDry System components.

Pre-Treatment Setup Procedures

Attach Handpiece to Console

Step-by-step guide on how to attach the miraDry Handpiece to the miraDry Console.

System Power and Navigation

Turning the System ON

Instructions on how to power on the miraDry System using the standby button.

Navigating the Touchscreen GUI

Guide on using the touchscreen interface to navigate through system operations and setup.

Adding Water to the System

Procedure for adding deionized or distilled water when prompted by the system.

System Self-Test and Placement

System Self-Test Procedure

How to position the Handpiece in the holster to initiate the system's self-test.

Preparing for Patient Treatment

Ensuring proper system positioning and vent obstruction check before patient treatment.

Gear Menu Operation

Accessing the Gear Menu

Instructions on how to access and use the Gear Menu icon on the Touchscreen GUI.

System Settings Configuration

Purge and BioTip Management

How to purge the bioTip and remove the bioTip from the Handpiece.

Energy Level and Brightness Adjustment

Adjusting microwave energy levels and touchscreen display brightness.

Console Volume and Session Stop

Controlling console volume and stopping a treatment session.

Microwave Energy Levels

Pre-Treatment Setup

Steps required before initiating patient treatment, including handpiece attachment.

Treatment Initiation and BioTip Attachment

Starting the Treatment Session

Instructions on how to start a treatment session using the system interface.

Attaching a New bioTip

Procedure for attaching a new bioTip to the Handpiece for a single treatment session.

BioTip Status Verification

Interpreting BioTip Status

Understanding the meaning of different bioTip status indicators on the GUI.

Anesthesia and Template Selection

Administering Anesthesia

Guidelines and precautions for administering local anesthesia before treatment.

Selecting Template Size

Procedure for measuring and selecting the appropriate template size for patient treatment.

Template Selection Modes

Simple Template Selection

Using system defaults for template size and treatment number for patient axillae.

Advanced Template Selection

Options for customizing template size and treatment mode for each axilla.

Applying Templates

Guided Treatment Mode Application

How to apply templates as described for Guided Treatment Mode.

Microwave Energy Level Selection

Selecting Energy Level for Treatment

Choosing the appropriate microwave energy level for patient treatment.

Treatment Screen and Template Changes

Treatment Screen Pop-up Reminder

Understanding the pop-up screen indicating treated side and template size.

Changing Template Size

Procedure for changing template size via the Change Template screen.

Axilla Preparation for Treatment

Lubricating the Axilla

How to apply lubricant to the patient's axilla before positioning the Handpiece.

Positioning the Handpiece

Correctly positioning the miraDry Handpiece on the patient's skin for treatment.

Starting the Treatment Cycle

Initiating Treatment Delivery

How to start the treatment cycle using the Handpiece handswitch or Console footswitch.

Normal Treatment Sequence

Guided Treatment Mode Sequence

Understanding the normal treatment cycle sequence and status bar indicators.

Stopping a Treatment Session

Stopping Treatment Mid-Placement

Methods to stop microwave energy delivery during a specific placement.

Session Termination and Emergency Stop

Terminating a Treatment Session

How to end a treatment session without completing all placements.

Emergency System Shutdown

Instructions for performing an instant system shutdown using the Emergency Stop Button.

Post-Treatment Procedures

Removing and Cleaning Handpiece

Steps for removing the bioTip and cleaning the Handpiece after treatment.

Treatment Summary and Ice Pack

Reviewing the treatment summary and applying an ice pack post-procedure.

Touch-up Mode Operation

Touch-up Treatment Setup

Instructions for selecting touch-up mode, template, and administering anesthesia.

Procedure Troubleshooting

Troubleshooting Treatment Start Issues

Resolving issues where the treatment cycle fails to start, including vacuum and contact checks.

Troubleshooting Vacuum Loss

Addressing problems related to loss of suction during the treatment cycle.

System Troubleshooting - Power Loss

Handling Power Loss Events

Procedures for dealing with power loss and system recovery.

Troubleshooting BioTip Errors

Resolving issues related to missing or invalid bioTips and confirming axilla.

System Shutdown and Training

System Shutdown Procedure

Steps to properly shut down the miraDry Console.

Training Requirements

Information on required in-field training for operating the miraDry System.

Cleaning and Disinfecting Procedures

Console Cleaning and Disinfection

Detailed instructions for cleaning and disinfecting miraDry Console components.

Storage and Maintenance

System Storage Guidelines

Recommendations for storing the miraDry System in a cool, dry place.

Maintenance and Fuse Replacement

Information on maintenance, service, and how to change console fuses.

System Components

MD4000-MC Console Components

List of components supplied with the miraDry MD4000-MC Console.

MiraDry System Components

List of additional components used with the miraDry System.

Troubleshooting Guide

Basic Error Recovery Steps

General steps to take when an error code or symbol appears on the GUI.

Troubleshooting Specific Error Codes

Solutions for common error codes related to power, communication, and handpiece issues.

Advanced Troubleshooting

BioTip Attachment and Vacuum Errors

Resolving issues with bioTip attachment and vacuum-related error conditions.

Water Level and Room Temperature Errors

Addressing errors related to low water level, air in cooling system, and high room temperature.

Technical Specifications

Device Dimensions and Power

Details on the physical dimensions, weight, and AC input specifications of the miraDry Console.

Operating and Environmental Parameters

Specifications for operating temperature, humidity, altitude, and pressure.

Safety and Compliance Standards

Information on the safety standards and compliance certifications the miraDry System adheres to.

Electromagnetic Compatibility (EMC)

EMC Guidance and Declarations

Information on ensuring electromagnetic compatibility with other medical devices.

Electromagnetic Immunity

Immunity Test Levels and Guidance

Details on immunity test levels and environmental guidance for the miraDry System.

RF Emissions and Separation Distances

Conducted and Radiated RF Immunity

Information on RF immunity levels and recommended separation distances from RF transmitters.