INSTALLATION, OPERATING INSTRUCTIONS AND OWNER’S MANUAL
READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION OF YOUR
WHIRLPOOL HYDROMASSAGE BATHTUB
PLEASE RECORD THE SERIAL NUMBER ______ OF YOUR WHIRLPOOL AND SAVE THIS MANUAL
FOR FUTURE REFERENCE.
NOTE: These instructions are to be used along with the installation instructions for
ACRYLIC BATHTUBS
WARNING - When using electrical products, basic
precautions should always be followed, including the
following:
"
Risk of electrical shock. Connect only to a DANGER:
circuit protected by a ground fault circuit interrupter, (GFCI).
"
Grounding is required. An equipment grounding terminal is
provided in the field wiring compartment. To reduce the risk of
electric shock, this terminal must be connected to the
grounding means provided in the electric supply panel with a
conductor equivalent in size to the circuit conductors
supplying the equipment.
"
Install this unit in accordance with the Canadian electrical
code, part 1 or the appropriate code in other countries.
"
Install to permit access for servicing.
"
Provide adequate ventilation for the motor to prevent
nuisance trips of the thermal overload protection.
Caution: Do not lift a whirlpool bath by its plumbing.
Handle it by the bath shell only.
DRAIN & OVERFLOW LEAK TEST
Test the installation after completing the plumbing, but before
enclosing the bath and finishing the surroundings. Fill the bath
with water and leave it for one hour to ensure that the
adjustment of the drain-overflow assembly is correct, and that
there are no leaks.
WHIRLPOOL FITTINGS LEAK TEST
Do not run the whirlpool pump unless the bath is filled with
water to a level at least 2" (50 mm) above the whirlpool fittings.
Press the tub-mounted air switch control (A/S) to start the
pump. Run the pump and jets for 10 minutes to ensure there
are no leaks around the whirlpool fittings. Press the air switch
control (A/S) again to stop.
INSTALLATION NOTES
Important: All Mirolin acrylic whirlpools receive a thorough
water test and are carefully inspected and packed for
shipment. You should check your unit for any problems. For all
installation and product related inquiries contact Mirolin
customer care at 800.MIROLIN before installation. Do not
contact retailer.
Protect the bathtub and fittings from dirt and damage by
leaving the polyethylene protective film in place until
installation and other related construction is complete. Access
for servicing the pump and controls of the whirlpool bath
must be provided (Refer to specification drawings for
location). DO NOT remove or relocate the pump from its
factory-installed position. This position ensures proper
priming, drainage, and performance of the whirlpool
system.
Relocating the pump will void the warranty.
NOTE: The unions for the piping at the pump are only to
be hand tightened. Check by hand that they have not
loosened during shipping.
MODELS WITH INTEGRAL APRON
Whirlpools with an integral apron have a removable
panel in the apron for access to the pump and motor. The
panel is fastened to the apron by strips of interlocking
fabric (velcro) along the top plus screws.
To remove panel follow instructions below:
Figure 1 - Integral apron with removable panel.
To remove the panel, first expose the screws by
removing all 5 plastic caps. Use a flat screwdriver gently
to avoid scratching the acrylic bathtub, Figure 2.
ACRYLIC WHIRLPOOLS
1
mirolin.com
Plastic cap
©
2018 Mirolin Industries Corp.

Other manuals for Mirolin Phoenix PA6030R

Question and Answer IconNeed help?

Do you have a question about the Mirolin Phoenix PA6030R and is the answer not in the manual?

Summary

Installation, Operation, and Owners Manual

General Safety Precautions

Covers basic electrical safety, grounding, and specific dangers like shock.

Leak Testing Procedures

Tests for leaks in the drain/overflow assembly and whirlpool fittings.

Integral Apron Model Access

Instructions for removing the panel on models with an integral apron.

Electrical Connections and Installation

Electrical Connection Requirements

Details on GFCI, conductor sizing, and wiring for whirlpool systems.

NEMA Receptacle Installation

Guidelines for installing NEMA receptacles, including exclusion zones.

Important Safety Instructions

Essential safety directives to be read, followed, and saved.

Operating and Health Guidelines

Safe Use and Health Considerations

Advice on bath use, physiological response, and consulting a physician.

Whirlpool System Operation

Instructions for air switch, jet adjustment, and motor protection.

In-Line Heater Functionality

Details on the heater's operation, temperature control, and safety.

Maintenance and Safety Warnings

Electrical Connection Diagram and GFCI Test

Diagram of electrical hookup and procedure for testing the GFCI.

Hyperthermia Risks and Prevention

Information on hyperthermia causes, symptoms, effects, and prevention.

Acrylic Surface and Fitting Maintenance

Guidance on cleaning, polishing, and repairing surfaces and fittings.

Cleaning and System Components

Clean and Purge Procedure

Recommended procedure to clean internal piping regularly.

Suction Return Fitting Diagram

Diagram illustrating the suction return fitting components.

Part Identification

Reference Whirlpool System Drawing

Key and part descriptions for the main whirlpool system diagram.

System Component Diagrams

Visuals of typical systems with and without back jets.

Mirolin Phoenix PA6030R Specifications

General IconGeneral
MaterialAcrylic
Length60 inches
Width30 inches
Drain LocationRight
ShapeRectangular
Installation TypeAlcove
ColorWhite
WarrantyLimited Lifetime