Table 2
Model
Sauna
volume
Safety distance, mm
Suitable
bottom plinth
The maximum
temperature
for flue gases
side
rear
front
up
11108
11108O
11108V
6 16
300
300
500
1200
19806
547 °C
11108 with
lateral water
tank 17100
6 16
300, on
tank
side
150
300
500
1200
19807
547 °C
11208
11208K
11208O
11208V
8 20
400
400
500
1250
19806
561 °C
11208 with
lateral water
tank 17200
8 20
400, on
tank
side
250
400
500
1250
19807
561 °C
11308
11308K
11308O
11308V
15 30
400
400
500
1250
19806
512 °C
11308 with
lateral water
tank 17300
15 30
400, on
tank
side
250
400
500
1250
19807
512 °C
Safety distances are measured from the product’s external surfaces.
Lateral and rear safety distances can be reduced by using Misa fire protection boards, product
No. 19808 and 19809.
When using single protection, the lateral or rear safety distance to the combustible material is
200 mm. When using double protection, the lateral or rear safety distance to the combustible
material is 100 mm. You can find more detailed instructions on use of the fire protection boards
in their manuals.
When using masonry or other protection, the dimensions must be verified with the
local fire inspector/building administrator.
MODELS 11208K AND 11308K, HEATED FROM ANOTHER ROOM
The wall through which the heater is used must be built from non-flammable, category A1
material. The wall must be non-flammable, to the extent of the entire height of the sauna, and at
least 125 cm in width (the width of the heater + safety distances on the sides).