EasyManua.ls Logo

Mita WP3000 - Page 5

Default Icon
7 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RS 232 communication
PS-Data April 29
th
2013 Page 5
Service menu
DataLog ctrl
Ser.# menu
Access list
Event list
Status count
Status list
Parameters
o Communication control
Baudrate Com1
Baudrate Com2
Baudrate Com3
Baudrate Com4 9600 (Can be between 1200 and 57600)
WP3033 Com1
WP3033 Com2
Com 5 not installed
Com 5 not installed
Node number 1 (Can be between 1 to 254)
RTS 4 always on 1
Ignore CTS 4 1
o Parkmaster-control
Select systemtype Select parkmaster
Init modem 5m
Mod.ini.1: Erase
Mod.ini.2: Erase
Connect time 60s
Filter park echo: 0
Park Id Park phone no
Alarm call control
Phone 1 Erase
Phone 2 Erase
Phone 3 Erase
Phone 4 Erase
Phone 5 Erase
Phone 6 Erase
Try 1-3 0 times
Try 4 0 times
Try 5 0 times
Try 6 0 times
Node number control
Add and remote node no
Alarm st. code 0 OFF
Grid
Status
Start menu