MAINPARAMETER
Model
Parameter
Inputpowervoltage(V)
Inputvoltagefrequency(HZ)
Ratedinputcurrent(A)
Ratedinputpowercapacity(KVA)
Outputcurrentrange(A)
No-loadvoltage(V)
Ratedoutputvoltage(V)
Pre-flowtime(S)
Clearwidth(%)
Down-slopetime(S)
Pulsewidth(%)
Pulsecurrentrange(A)
Pulsefrequencyrange(HZ)
Post-gastime(S)
Arc-striking HF HF
Efficiency(%)
Dutycycle(%)
Powerfactor
Insulationclass
Protectionclass
Weight(KG)
Dimension(mm)
SUPERSeries·User’sManual
-12-
INSTALLMENT&OPERATION
Theratedcurrentandthediameteroftheoutputcable
(max.temperatureofconductor60
)
Ratedcurrentofthemax.dutycycle(A)
Ratedsectionof
copperconductor
(mm
2
)
100% 85% 60% 30% 20%
16 105 115 135 190 235
25 135 145 175 245 300
35 170 185 220 310 380
50 220 240 285 400 490
70 270 195 350 495 600
95 330 360 425 600 740
120 380 410 490 690 850
185 500 540 650 910 1120
Thesectionandthelengthoftheweldingcable
Section(mm
2)
Rated
current(L/A)
100 25 25 25 25 25 25 25 28 35
150 35 35 35 35 50 50 60 70 70
200 35 35 35 50 60 70 70 70 70
300 35 50 60 60 70 70 70 85 85
400 35 50 60 70 85 85 85 95 95
500 50 60 70 85 95 95 95 120