The Mito Red Light Flexible Devices User Manual describes a range of red and near-infrared light therapy products designed to promote overall health and wellness by supporting cellular function. These devices are general wellness products and are not intended to diagnose, treat, cure, or prevent any medical conditions.
Function Description:
Red and near-infrared light therapy works by exposing the body to specific wavelengths of light (630nm, 660nm, 810nm, 850nm). These photons interact with cytochrome c oxidase within cells, leading to more efficient oxygen use by mitochondria. This process increases the production of ATP (adenosine triphosphate), which is essential for various cellular processes like muscle contraction, nerve impulse propagation, and chemical synthesis. By boosting cellular energy, the devices aim to improve overall bodily performance.
Important Technical Specifications:
Advanced Red Light Therapy Belt:
- Battery Capacity: 15,000 mAh
- Light Split: 50/50 Red / NIR
- LEDs: 405 diodes with 3 chips per diode, totaling 1,215 LED chips per belt.
- Wavelengths: 660nm (Red) & 850nm (NIR)
- Intensity: 5 adjustable intensity levels.
- Power Input: 120V (can be used internationally with a plug adapter).
- Charge Power Output: 12V
- Weight: 1.5 pounds
- Dimensions: 48"x7"
- Treatment Area Dimensions: 21" x 5"
- Battery Life: Runs 2-6 hours on a single charge (depending on intensity level selected).
- Warranty: 1 Year
Quad Wavelength Belt:
- Battery Capacity: 15,000 mAh
- Light Split: 67% NIR, 33% Red
- LEDs: 405 diodes with 3 chips per diode, totaling 1,215 LED chips per belt.
- Wavelengths: 630nm, 660nm (Red) & 810nm, 850nm (NIR)
- Brightness: 1%-100% adjustable.
- Power Input: 120V (can be used internationally with a plug adapter).
- Charge Power Output: 12V
- Weight: 1.5 pounds
- Dimensions: 52"x7"
- Treatment Area Dimensions: 22" x 6"
- Battery Life: Runs 2-6 hours on a single charge (depending on intensity level selected).
- Warranty: 1 Year
Full Body Mat:
- Light Split: 50/50 Red / NIR
- LEDs: 1,280
- Wavelengths: 660nm (red) and 850nm (NIR)
- Brightness: 1%-100% adjustable.
- Input Voltage & Power: 100V-240V, 50-60HZ, 97 Watt
- Weight: 7 pounds
- Dimensions: 62" x 24"
- Timer: 1-30 minutes
- Driver: 24V 5A, UL
- Material: Neoprene
- Power Source: Runs on power supply from electrical outlet.
- Warranty: 1 year
Usage Features:
General Usage Guidance for All Devices:
- First-Time Users: Start with 4-5 minute treatments per area, gradually increasing to 10-15 minutes over 2-3 weeks as the body acclimates.
- Standard Use: Recommended 10-15 minute treatments per area. Additional 10-minute sessions for specific areas may be beneficial, but prolonged use beyond a certain point may lead to diminishing returns.
- Frequency: Allow at least 6 hours between treatments of the same area. Do not exceed 30 minutes in any one session. Use the device 4-10 times per week, with at least one day off per week.
Advanced Therapy Belt and Quad Belt:
- Powering with Wall Adapter:
- Connect the male end of the remote control cable to the DC power port on the belt.
- Connect the wall power adapter to the female end of the remote control cable.
- Plug the power adapter into a standard wall outlet.
- Power on/off by holding the remote button for 3 seconds.
- Unplug from the wall outlet after use.
- Powering with External Battery:
- Connect the male end of the remote control cable to the DC power port on the belt.
- Connect the skinny male plug from the jumper cable to the battery pack port, then connect the larger male end to the remote's female port.
- To power on, press the power button on the side of the power bank once, then hold the remote power button for 3 seconds.
- Place the battery in the belt's front pocket during use.
- To power off, hold the remote power button for 3 seconds, then hold the power button on the battery pack for 3 seconds.
- Remote Control (Advanced Belt):
- Intensity Options: Five settings (LO, L1, L2, L3, L4). Start with a lower setting and adjust for comfort.
- Timer Options: 5, 10, 15, 20, 25, 30 minutes, in 5-minute increments.
- Mode Setting: Choose between 660nm, 850nm, or All.
- Switch: On/Off button.
- Remote Control (Quad Belt):
- Brightness Option: Adjustable from 1-100%. Start with lower brightness.
- Timer Options: 1-30 minutes, in 1-minute increments.
- Controls: Increase/Decrease Time, Change Mode, Increase/Decrease Brightness, Start/Stop Treatment, Bring up settings menu/Switch between settings.
Full Body Mat:
- Powering:
- Connect the male end of the remote cord to the cord attached to the mat, aligning slots, pressing firmly, and tightening the middle wheel.
- Connect the female end of the remote cord to the power adapter cord, aligning slots, pressing firmly, and tightening the middle wheel.
- Plug the power adapter into a standard wall outlet.
- Remote Control: Similar to the Quad Belt, with brightness 1-100% and timer 1-30 minutes in 1-minute increments.
Maintenance Features:
Cautions & Disclaimer:
- Storage: Store in a cool, dry place to preserve life and functionality.
- Safety Precautions:
- DO NOT allow children to use without adult supervision.
- DO NOT use on infants.
- DO NOT allow sleeping, disabled, or unconscious persons to use.
- DO NOT exceed 20 minutes per therapy session.
- DO NOT use on open, fresh wounds.
- DO NOT use with heat-producing liniments, salves, ointments, or balms to avoid skin burns.
- DO NOT modify or attempt to repair the equipment; no user-serviceable parts.
- DO NOT wash electrical parts with water or other liquids.
- DO NOT drop the device or components (e.g., battery) into water or other liquids.
- DO NOT expose to running water. If submerged, unplug immediately. Use with a Ground Fault Circuit Interrupter (GFCI) protected outlet if near water.
- DO NOT directly touch the light, plugs, or switches with wet hands.
- DO NOT apply or touch the light to wet or damp skin.
- DO NOT pull, carry, or lift the light by its cord. Discontinue use if the cord is damaged.
- DO NOT use on or near heated surfaces.
- DO NOT operate in areas with flammable or combustible products or vapors to prevent explosion or fire.
- DO NOT store or use in temperatures exceeding 120 degrees Fahrenheit.
- DO NOT use if damaged; continuous use of a damaged light may result in electric shock or injury.
- DO NOT use extension cords unless designed for the light's total wattage.
- DO NOT unplug by pulling the cord; grasp the plug itself.
- Consult Healthcare Provider: Recommended before use if sensitive to light, pregnant, have suspicious or cancerous lesions, recently had a steroid injection, use topical steroids, or take medications that cause light sensitivity (cold, allergy, pain, infection medications).
- Discomfort: Stop use immediately and contact a healthcare provider if discomfort or concerns arise.
- Tripping Hazards: Unplug from the outlet when not in use.