EasyManua.ls Logo

Mitsubishi Electric CITY MULTI PKFY-P30NKMU-E User Manual

Mitsubishi Electric CITY MULTI PKFY-P30NKMU-E
37 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
CITY MULTI
DATA U5
SYSTEM DESIGN H SERIES
SYSTEM DESIGN H SERIES
1. Electrical work.................................................................................................................................................. 4 - 68
1-1.General cautions ....................................................................................................................................... 4 - 68
1-2.Power supply for Indoor unit and Outdoor unit .......................................................................................... 4 - 69
1-3.Power cable specifications ........................................................................................................................ 4 - 71
1-4.Power supply examples............................................................................................................................. 4 - 72
2. M-NET control.................................................................................................................................................. 4 - 74
2-1.Transmission cable length limitation.......................................................................................................... 4 - 74
2-2.Transmission cable specifications............................................................................................................. 4 - 75
2-3.System configuration restrictions............................................................................................................... 4 - 76
2-4.Address setting.......................................................................................................................................... 4 - 79
3. Piping Design................................................................................................................................................... 4 - 90
3-1.R410A Piping material............................................................................................................................... 4 - 90
3-2.Piping Design ............................................................................................................................................ 4 - 91
3-3.Refrigerant charging calculation................................................................................................................ 4 - 93
4. Outdoor Installation.......................................................................................................................................... 4 - 94
4-1.Requirement on installation site ................................................................................................................ 4 - 94
4-2.Spacing...................................................................................................................................................... 4 - 95
4-3.Piping direction.......................................................................................................................................... 4 - 97
4-4.Weather countermeasure.......................................................................................................................... 4 - 102
5. Caution for refrigerant leakage ........................................................................................................................ 4 - 103
5-1.Refrigerant property................................................................................................................................... 4 - 103
5-2.Confirm the Critical concentration and take countermeasure.................................................................... 4 - 103
4 - 67
Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Electric CITY MULTI PKFY-P30NKMU-E and is the answer not in the manual?

Mitsubishi Electric CITY MULTI PKFY-P30NKMU-E Specifications

General IconGeneral
BrandMitsubishi Electric
ModelCITY MULTI PKFY-P30NKMU-E
CategoryAir Conditioner
LanguageEnglish

Summary

Electrical Work and Specifications

General Cautions for Electrical Installation

General precautions for electrical work, wiring, and grounding.

Indoor and Outdoor Unit Power Supply Details

Power supply characteristics and voltage ranges for indoor and outdoor units.

Power Cable and Wire Specifications

Guidelines for power cable selection, thickness, and protection.

Electrical Power Supply Connection Examples

Illustrative examples of power supply connections for various system setups.

M-NET Communication and Control System

M-NET Transmission Cable Length Limits

Maximum permissible lengths for M-NET transmission cables to ensure reliable communication.

M-NET Transmission Cable Specifications

Details on cable types, sizes, and shielding for M-NET communication.

System Configuration and Communication Restrictions

Guidelines for system configuration, power supply, and restrictions for M-NET communication.

Unit Address Setting Rules

Procedures and rules for setting unit addresses for proper system identification and operation.

Refrigerant Piping Design and Material

R410A Refrigerant Pipe Material Standards

Specifies acceptable copper pipe types and radial thickness for R410A systems.

Piping Design Schemes and Component Selection

Details piping layouts, lengths, and selection of joints/headers for specific models.

Calculating Additional Refrigerant Charge

Formula and method for calculating the extra refrigerant needed based on piping length.

Outdoor Unit Installation Requirements

Installation Site Selection Criteria

Guidelines for choosing an appropriate location for outdoor unit installation.

Outdoor Unit Spacing and Clearances

Recommended minimum clearances around outdoor units for airflow and service access.

Piping Routing and Handling of Outdoor Units

Methods for lifting, transporting, and connecting outdoor units safely.

Weather Protection Measures for Outdoor Units

Strategies for protecting units from snow, wind, and freezing conditions.

Refrigerant Leakage Safety and Countermeasures

R410A Refrigerant Properties and Critical Concentration

Information on R410A properties and critical concentration limits for safe operation.

Assessing and Mitigating Refrigerant Leakage Risks

Procedure for calculating leakage concentration and implementing safety measures.