CYLINDER UNIT
EHST20 series
EHPT20 series
ERST20 series
HYDROBOX
EHSC series EHSD series
EHPX series ERSC series
ERSD series
MODE D'EMPLOI
Pour garantir une utilisation sûre et appropriée, lisez attentivement le présent mode d'emploi avant d'utiliser
l’ECODAN hydrobox duo et l’ECODAN hydrobox.
BEDIENUNGSANLEITUNG
Lesen Sie sich zur sicheren und korrekten Verwendung diese Bedienungsanleitung bitte sorgfältig durch,
bevor Sie das Hydraulikmodul inkl. Speicher und die Hydrobox verwenden.
FÜR NUTZER
OPERATION MANUAL
For safe and correct use, please read this operation manual thoroughly before operating the cylinder unit and
the hydrobox.
HANDLEIDING
Voor een veilig en juist gebruik moet u deze handleiding goed doorlezen alvorens de cilinder en hydrobox in
gebruik te nemen.
MANUAL DE INSTRUCCIONES
Para un uso correcto y seguro del hydrobox duo y del Hydrobox, lea este manual de instrucciones antes de su
utilización.
MANUALE DI FUNZIONAMENTO
Per un uso corretto e sicuro del dispositivo, leggere attentamente il presente manuale di funzionamento prima
di utilizzare l’hydrotank e l’hydrobox.
MANUAL DE FUNCIONAMENTO
Para uma utilização segura e correcta, é favor ler cuidadosamente este manual de funcionamento antes de
trabalhar com o cilindro e permutador de calor.
BRUGSVEJLEDNING
Læs venligst denne brugsvejledning grundigt inden betjening af i tank modulet (unit) og hydroboksen.
ANVÄNDARMANUAL
För säker och korrekt användning, var god läs denna användarmanual noggrant innan du använder i cylindertanken
och hydroboxen.
BRUKSANVISNING
Les denne bruksanvisningen nøye før du bruker sylinderenheten og hydroboksen for å sikre trygg og riktig
bruk.
KÄYTTÖOPAS
Turvallisen ja asianmukaisen käytön varmistamiseksi lue tämä käyttöopas huolellisesti ennen varaajayksikön
ja hydroboxin käyttöä.
KÄYTTÄJÄLLE
FOR BRUKEREN
FOR USER
POUR LES UTILISATEURS
VOOR DE GEBRUIKER
PARA EL USUARIO
PER L’UTENTE
PARA O UTILIZADOR
TIL BRUGER
FÖR ANVÄNDAREN
English (EN)
(RU)
Español (ES)
Italiano (IT)
Português (PT)
Dansk (DA)
Svenska (SV)
Norsk (NO)
Suomi (FI)
Deutsch (DE)
Français (FR)
Nederlands (NL)

Для безопасного и корректного использования внимательно прочитайте эту инструкцию по эксплуата-
ции гидромодулей.


NÁVOD K OBSLUZE
V zájmu bezpečného a správného používání si prosím pečlivě prostudujte tento Návod k obsluze, dříve než
začnete zásobníkový modul a hydromodul uvádět do provozu.
Pro provozovatele
Polski (PL)

Warunkiem bezpieczeństwa i poprawności użytkowania modułu wewnętrznego z wbudowanym i bez
wbudowanego zasobnika CWU jest uprzednie uważne przeczytanie niniejszej instrukcji obsługi.


Questions and Answers

  • W
    Willie HannaJul 30, 2025
    Why is my Mitsubishi Electric EHST20C- VM2C heating system not reaching the set temperature?
    • M
      Mary MarshallJul 31, 2025
      If your Mitsubishi Electric Heat Pump's heating system isn't reaching the set temperature, check if a prohibit, schedule, or holiday mode is active. Adjust the settings as needed. Also, the room with the temperature sensor might be at a different temperature than the rest of the house, so consider repositioning the sensor. If you are using wireless control, check and replace the battery if needed.
  • L
    Lisa TorresAug 3, 2025
    Why isn't my Mitsubishi Electric EHST20C- VM2C cooling system reaching the set temperature?
    • L
      Lindsay BestAug 3, 2025
      If your Mitsubishi Electric Heat Pump's cooling system isn't cooling down to the set temperature (ONLY for ERSC(D) and ERST20C(D) models), it could be due to a delay at the start of cooling mode to protect the outdoor unit when the water in the circulation circuit is unduly hot. This is normal operation. Also, when the outdoor ambient temperature is significantly low, cooling mode does not start running to avoid freezing of the water pipes.
  • L
    Laura JamesAug 8, 2025
    What to do if an error code appears on my Mitsubishi Electric EHST20C- VM2C?
    • C
      Chris MaxwellAug 8, 2025
      If an error code appears on your Mitsubishi Electric Heat Pump's main remote controller display, it indicates an abnormal condition reported by either the indoor or outdoor unit. Note the error code number and contact your installer for assistance.
  • T
    Thomas MorrisAug 12, 2025
    What to do if water discharges from the relief valves of my Mitsubishi Electric EHST20C- VM2C?
    • L
      lisa02Aug 12, 2025
      If water discharges from one of the relief valves of your Mitsubishi Electric Heat Pump, it means the system has likely overheated or is overpressurized. Immediately switch off the power to the heat pump and any immersion heaters, then contact your installer.
  • B
    Brenda CarterAug 17, 2025
    Why is my Mitsubishi Electric EHST20C- VM2C Heat Pump relief valve dripping?
    • N
      Natalie HenryAug 17, 2025
      If you notice small amounts of water dripping from one of the relief valves of your Mitsubishi Electric Heat Pump, dirt may be preventing a tight seal. Twist the valve cap in the indicated direction until you hear a click to release a small amount of water, flushing out any dirt. Be careful, as the released water will be hot. If the valve continues to drip, the rubber seal may be damaged and need replacing, so contact your installer.
  • J
    Jennifer StevensonAug 21, 2025
    Why is the water cold at the taps with my Mitsubishi Electric Heat Pump?
    • W
      wilsonannAug 21, 2025
      If you are experiencing cold water at the taps when using a Mitsubishi Electric Heat Pump with a DHW tank, first check your schedule settings and adjust them if necessary. If that's not the issue, it's possible all the hot water from the DHW tank has been used; ensure the DHW mode is operating and wait for the tank to reheat.
  • M
    michelle81Aug 25, 2025
    Why is my Mitsubishi Electric EHST20C- VM2C heating emitter hot in DHW mode?
    • S
      scott44Aug 26, 2025
      If the heating emitter is hot in DHW mode, causing the room temperature to rise with your Mitsubishi Electric Heat Pump, it may be because the 3-way valve has foreign objects in it, or hot water may be flowing to the heating side due to malfunctions.

Summary

Safety Precautions and Disposal

Unit Disposal Guidelines

Information on how to dispose of the unit and associated batteries correctly according to regulations.

Introduction to Heat Pump Systems

System Components Overview

Describes the key components of the Mitsubishi Electric Air to Water (ATW) heat pump system.

Heat Pump Working Principle

Explains the vapour-compression cycle and how heat pumps generate heat from the environment.

Economical Operation Best Practices

Tips for achieving the most efficient and economical operation of the heating system.

Key Heat Pump System Considerations

Key considerations for domestic hot water and legionella functions and system limitations.

Control System Functionality

Explains the Flow Temperature Controller (FTC) and its role in managing system operation.

Product Specifications

Cylinder Unit Specifications

Details specifications for various Cylinder unit models including dimensions, weight, and performance data.

Hydrobox Unit Specifications

Details specifications for various Hydrobox unit models including dimensions, weight, and electrical data.

Customising Your Home Heating System

Main Remote Controller Interface

Details the parts and functions of the main remote controller for system adjustments and status checks.

System Operation and Settings

Covers general operation, option screen, main settings menu, and initial configuration steps.

Advanced Configuration Options

Includes settings for room sensors and advanced features for optimized system performance.

Domestic Hot Water & Legionella Control

Controls domestic hot water heating and legionella prevention modes for hygiene and comfort.

Specific Operational Modes

Covers Forced DHW, Heating/Cooling modes, and compensation curve settings for efficient operation.

Holiday Mode and Schedule Timers

How to use Holiday Mode and set up schedule timers for energy saving and automation.

Service Menu Access

Explains the password-protected service menu for qualified personnel only.

Service and Maintenance

Troubleshooting Common Issues

Table of common faults, their causes, and recommended solutions provided by the installer.

Routine Maintenance Procedures

Details annual servicing requirements and parts inspection/replacement by a competent person.

Mitsubishi Electric EHST20C- VM2C Specifications

General IconGeneral
BrandMitsubishi Electric
ModelEHST20C- VM2C
CategoryHeat Pump
LanguageEnglish