EasyManua.ls Logo

Mitsubishi Electric FR-A740-01800-EC User Manual

Mitsubishi Electric FR-A740-01800-EC
105 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
FR-A7NF INSTRUCTION MANUAL
D
INVERTER
INVERTER
Plug-in option
INSTRUCTION MANUAL
INVERTER
1
2
3
4
5
6
7
8
9
HEAD OFFICE: TOKYO BUILDING 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
FR-A7NF
FL remote
communication
function
IB(NA)-0600328ENG-D(1111) MEE Printed in Japan Specifications subject to change without notice.
PRE-OPERATION INSTRUCTIONS
INSTALLATION
WIRING
INVERTER SETTING
FL REMOTE COMMUNICATION
FUNCTION
CYCLIC TRANSMISSION
DESCRIPTION AND CORRECTIVE
ACTION OF FAULT INDICATION
MESSAGE TRANSMISSON
TROUBLESHOOTING

Table of Contents

Other manuals for Mitsubishi Electric FR-A740-01800-EC

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Electric FR-A740-01800-EC and is the answer not in the manual?

Mitsubishi Electric FR-A740-01800-EC Specifications

General IconGeneral
BrandMitsubishi Electric
ModelFR-A740-01800-EC
CategoryAir Conditioner
LanguageEnglish

Summary

INSTALLATION

2.1 Pre-installation instructions

Crucial safety and preparation steps before installation.

2.3 Installation procedure

Detailed steps for physically installing the plug-in option.

2.4 Node address setting

Instructions on setting the unique node address for network communication.

WIRING

3.1 Connection to network

Procedures for connecting the inverter to the FL remote network.

3.4 Wiring

Guides on routing wires for different inverter configurations.

INVERTER SETTING

4.2 Operation mode setting

Explains how to set the inverter's operation mode (Network, PU, External).

4.3 Selection of control source for the Network operation mode

How to select command and speed sources in Network mode.

4.4 Operation at communication error occurrence

Defines inverter behavior and settings during communication errors.

4.4.2 Fault and measures

Describes inverter operations based on different fault locations and statuses.

4.5 Inverter reset

Explains different methods and conditions for resetting the inverter.

CYCLIC TRANSMISSION

6.2.1 Control input command

Defines commands for controlling inverter operations like rotation.

6.3.2 Fault code

Provides descriptions for various inverter fault codes.

DESCRIPTION AND CORRECTIVE ACTION OF FAULT INDICATION

(1) Fault

Describes fault indications like E.OPT and provides corrective actions.

TROUBLESHOOTING

General troubleshooting

General guidance for locating and correcting faults.

E.1, E.2, E.3 Faults

Troubleshooting steps for specific error codes E.1, E.2, E.3.

E.OPT Faults

Troubleshooting steps for the E.OPT fault indication.

E.OP1, E.OP2, E.OP3 Faults

Troubleshooting steps for error codes E.OP1, E.OP2, E.OP3.

0.00 Faults

Troubleshooting for communication establishment issues indicated by 0.00.

Related product manuals