Contents
1. Safety precautions ............................................ 2-3
1.1. Installation ................................................... 2
1.2. During operation ......................................... 3
1.3. Disposing of the unit ................................... 3
2. Names and functions of various parts ...............4-6
3. How to operate ..................................................7-9
3.1.
When interlocked with an indoor unit .................
7
3.2.
When not interlocked with an indoor unit ...........
7
3.2.1. Before starting operation ....................... 7
3.2.2. ON/OFF ................................................. 7
3.2.3. Selecting operation ................................ 7
3.2.4. Temperature adjustment ........................ 8
3.2.5. Fan speed adjustment ........................... 8
3.2.6. Time setting ........................................... 8
3.2.7. Timer setting .......................................... 9
4. Cleaning the machine ................................... 10-11
5. Inspection and maintenance
(GUF-50-100RDH3 only) .............................. 11-13
6. Troubleshooting ................................................. 13
7.
Installation and transferring works, and checking ....
14
8. Specifications ..................................................... 14
Fresh Master
Models:
GUF-50RDH3
GUF-50RD3
GUF-100RDH3
GUF-100RD3
Operating Instructions
(For the user)
For use with the R410A & R407C & R22
Please read through these instructions in order to famil-
iarize yourself with the proper and safe procedures for
operating the Fresh Master.
After reading this manual, keep it in an easily accessible
and safe place for future reference.
The warranty will not apply to damage resulting
from failure to follow the warnings and precau-
tions included in the Operating Instructions.
GUF-50RDH3 shown above.
Humidifier function not available on GUF-50RD3 and
GUF-100RD3.

Other manuals for Mitsubishi Electric Fresh Master GUF-100RDH3

Questions and Answers:

Mitsubishi Electric Fresh Master GUF-100RDH3 Specifications

General IconGeneral
Cooling Capacity10.0 kW
Heating Capacity11.2 kW
RefrigerantR410A
Weight (Indoor Unit)32 kg
Weight (Outdoor Unit)98 kg
Indoor Unit Noise Level42 dB

Summary

Safety Precautions

Installation Safety Guidelines

Precautions for safe installation, including unit placement, grounding, and power supply.

Operation Safety and Procedures

During Operation Safety

Safety measures to follow while the unit is operating to prevent injury or damage.

Operating the Fresh Master

Selecting Operation Mode

How to select between cooling, fan, automatic, and heating modes.

Temperature Adjustment

How to set the desired temperature for cooling and heating.

Time and Timer Settings

How to set the current time and basic timer functions.

Advanced Timer Settings

Detailed instructions on setting specific ON-timer, OFF-timer, and ON/OFF timers.

Machine Cleaning Procedures

Cleaning Air Filters and Lossnay Cores

Instructions for cleaning the air filters and Lossnay cores.

Inspection and Maintenance

Maintenance Inspection Items

Details of inspection items for strainer, humidifying elements, and their consequences if not maintained.

Cleaning Preparation Steps

Steps to prepare the unit for maintenance, including closing valves and draining water.

Humidifying Element Removal

Step-by-step guide to safely remove humidifying elements from the unit.

Troubleshooting Guide

Common Issues and Solutions

A table listing common problems, their causes, and corresponding troubleshooting steps.

Installation and Technical Details

Electrical Work Requirements

Precautions and requirements for electrical connections, including grounding.