Do you have a question about the Mitsubishi Electric FR-D720-0.1K and is the answer not in the manual?
Model | FR-D720-0.1K |
---|---|
Series | FR-D700 |
Input Voltage | 200-240V AC |
Rated Output Power | 0.1 kW |
Input Frequency | 50/60 Hz |
Protection Class | IP20 |
Cooling Method | Fan cooled |
Output Voltage | 3-phase 200-240V AC |
Output Frequency | 0.5 to 400 Hz |
Control Method | V/F control |
Details on how to check the inverter and identify its parts and accessories, including rating plate examples.
Information on peripheral devices that can be connected to the inverter, such as reactors, noise filters, and brake units.
Instructions for removing and reinstalling the front and wiring covers of the inverter for maintenance or access.
Guidelines for designing enclosures and installing the inverter in various environments to ensure proper operation.
Information on leakage currents and countermeasures, including selection of earth leakage current breakers and EMC measures.
Guidance on installing reactors (FR-HAL, FR-HEL) to prevent peak current and ensure reliable performance.
Essential precautions for safe operation and handling of the inverter to prevent damage or shortened lifespan.
Methods for implementing failsafe systems using inverter status output signals to prevent accidents.
Details on the names and functions of the operation panel buttons, indicators, and display elements.
Comprehensive list of all available parameters, their settings, initial values, and references for detailed explanation.
Procedures for adjusting output torque, including manual torque boost and magnetic flux vector control settings.
Methods for setting maximum and minimum output frequencies and avoiding mechanical resonance points using frequency jumps.
Diagrams and instructions for connecting power and control circuits, including terminal specifications and notes on noise prevention.
Detailed specifications for main circuit terminals, including power supply and motor wiring arrangements for various models.
Information on control circuit terminals, including input/output signals, communication interfaces, and safety stop functions.
Instructions for connecting external option units like brake resistors, brake units, converters, and reactors.
Guidelines for daily and periodic inspections to prevent inverter faults and ensure safe operation and part longevity.
Procedures for measuring voltages, currents, and powers using various instruments and techniques.
Technical specifications including applicable motor capacity, rated voltage, and current for different power supplies and models.
General specifications covering control methods, frequency settings, input/output signals, and environmental conditions.
Dimensional drawings and panel cutouts for various inverter models and optional units, including mounting information.