EasyManua.ls Logo

Mitsubishi Electric FR-D740-0.75K User Manual

Mitsubishi Electric FR-D740-0.75K
313 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
3
4
5
6
7
1
2
FR-D700
INSTRUCTION MANUAL (Applied)
INVERTER
PRECAUTIONS FOR USE
OF THE INVERTER
PARAMETERS
TROUBLESHOOTING
PRECAUTIONS FOR
MAINTENANCE AND INSPECTION
SPECIFICATIONS
OUTLINE
WIRING
HEAD OFFICE: TOKYO BUILDING 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
MODEL
MODEL
CODE
1A2-P35
FR-D700
INSTRUCTION MANUAL (Applied)
FR-D720-0.1K to 15K
FR-D740-0.4K to 15K
FR-D720S-0.1K to 2.2K
FR-D710W-0.1K to 0.75K
IB(NA)-0600366ENG-G (1207)MEE Printed in Japan Specifications subject to change without notice.
INVERTER FR-D700 INSTRUCTION MANUAL (Applied)
G

Table of Contents

Questions and Answers:

Mitsubishi Electric FR-D740-0.75K Specifications

General IconGeneral
ModelFR-D740-0.75K
SeriesFR-D700
Applicable Motor Capacity (kW)0.75
Rated Output Power0.75 kW
Frequency Range0.2 to 400 Hz
Overload Capacity150% for 60 seconds
Protection StructureIP20
Operating Temperature-10 to +50°C
Storage Temperature-20 to +65°C
Humidity90% RH or less (non-condensing)
Altitude1000 m or less
Enclosure RatingIP20
Input Voltage3-Phase 380 to 480 V AC
Output Voltage3-Phase 380 to 480 V AC
Control MethodV/F control, vector control
Protection FeaturesOvercurrent, overvoltage, overheat
Cooling MethodFan Cooled

Summary

OUTLINE

Product checking and parts identification

Unpack and check the capacity plate and rating plate to ensure the product agrees with the order and is intact.

Installation of the inverter and enclosure design

Considerations for designing enclosures, environmental standards, and measures for temperature, humidity, dust, etc.

PRECAUTIONS FOR USE OF THE INVERTER

EMC and leakage currents

Discusses leakage currents, their countermeasures, and line-to-line leakage currents.

Precautions for use of the inverter

Covers essential precautions for wiring, operation, and handling to prevent damage or shorten product life.

Failsafe of the system which uses the inverter

Details methods for detecting inverter faults and implementing system safeguards.

PARAMETERS

Parameter list

Comprehensive list of all parameters, their settings, and related pages for detailed information.

Adjustment of the output torque (current) of the motor

Details how to adjust torque boost and manage output current for optimal motor performance.

Frequency setting by external terminals

Describes methods for setting frequency using multi-speed operation, jog operation, and remote settings.

Setting of acceleration/deceleration time and acceleration/deceleration pattern

Explains how to set acceleration/deceleration times and patterns, including S-pattern options.

Selection and protection of a motor

Covers motor overheat protection and selection of applied motors, including auto-tuning.

Motor brake and stop operation

Details DC injection brake, regenerative brake selection, and stop selection methods.

Function assignment of external terminal and control

Explains how to assign functions to input and output terminals, including safety stop signals.

Operation selection at power failure and instantaneous power failure

Explains automatic restart and power-failure deceleration stop functions.

Operation setting at fault occurrence

Details retry functions and phase loss/earth fault detection settings.

Frequency setting by analog input (terminal 2, 4)

Explains how to select and configure analog inputs for frequency setting and control.

Misoperation prevention and parameter setting restriction

Provides functions to prevent misoperation, such as reset selection, PU disconnection detection, and parameter write disable.

Selection of operation mode and operation location

Explains how to select operation modes (PU, External, Network, Combined) and control sources.

Communication operation and setting

Details wiring and configuration for PU connector communication and RS-485 communication.

Special operation and frequency control

Covers advanced functions like PID control, dancer control, and regeneration avoidance.

PID control (Pr. 127 to Pr. 134, Pr. 575 to Pr. 577)

Explains PID control for process applications like flow rate, air volume, or pressure.

Dancer control (Pr. 44, Pr. 45, Pr. 128 to Pr. 134)

Details dancer control by feedbacking position detection of the dancer roller.

Regeneration avoidance function (Pr. 665, Pr. 882, Pr. 883, Pr. 885, Pr. 886)

Describes how to avoid regenerative status by automatically increasing frequency when DC bus voltage rises.

Parameter clear/ All parameter clear

Resets parameters to initial values, including calibration and communication settings.

Check and clear of the faults history

Explains how to view past faults and clear the faults history.

TROUBLESHOOTING

Reset method of protective function

Provides methods to reset the inverter after a fault, including using the operation panel or RES signal.

List of fault or alarm indications

Lists all fault and alarm indications displayed on the operation panel, with corresponding names and refer pages.

Causes and corrective actions

Provides a detailed breakdown of possible causes for errors and their corresponding corrective actions.

Check first when you have a trouble

Offers a systematic approach to diagnosing and resolving common issues when the cause is unknown.

Motor current is too large

Discusses causes for high motor current, including torque boost, load issues, and auto-tuning.

Unable to write parameter setting

Explains why parameter writes might fail, including stop conditions, operation modes, and key lock settings.

PRECAUTIONS FOR MAINTENANCE AND INSPECTION

Measurement of main circuit voltages, currents and powers

SPECIFICATIONS

Rating

Provides detailed specifications for three-phase 200V, three-phase 400V, single-phase 200V, and single-phase 100V power supplies.

REVISIONS

FR-D700 Series Instruction Manual Supplement

Details specifications added for FR-D700 series manufactured from March 2014 onwards.

Related product manuals