ADVANCED AND EVER ADVANCING
MITSUBISHI ELECTRIC
MITSUBISHI
ELECTRIC
SPLIT-TYPE AIR CONDITIONERS
OPERATING INSTRUCTIONS
MS09TW
MS12TN
MS15TN
MS17TN
For customers
Thank you very much for purchasing this Mitsubishi room air conditioner.
To use this unit correctly and safely, be sure to read this operating instructions before use. Keep this manual carefully for
later reference.
Be sure to receive a guarantee card from your dealer and check that the purchased data and shop name, etc. are
entered correctly.
This air conditioner should not be installed by the customer. (Safety and performance functions cannot be assured.)
CONTENTS
SAFETY PRECAUTIONS 2
NAME OF EACH PART 4
PREPARATION BEFORE OPERATION 6
I FEEL... AUTO OPERATION 7
MANUAL OPERATION (COOL,DRY,FAN) 8
AIR FLOW VELOCITY AND DIRECTION ADJUSTMENT 9
TIMER OPERATION (ON/OFF TIMER) 10
WHEN THE AIR CONDITIONER IS NOT GOING TO BE
USED FOR A LONG TIME 10
MAINTENANCE 11
CLEANING THE AIR FILTER/DEODORIZING FILTER (OPTION) .... 11
REPLACEMENT OF THE DEODORIZING FILTER (OPTION)/
AIR CLEANING FILTER (OPTION) 12
BEFORE CONTACTING THE SERVICEMAN,
CHECK THE FOLLOWING AGAIN 12
WHEN YOU THINK THAT TROUBLE HAS OCCURRED 13
INSTALLATION, RELOCATION AND INSPECTION 14

Other manuals for Mitsubishi Electric Mr. Slim MS09TW

Questions and Answers:

Mitsubishi Electric Mr. Slim MS09TW Specifications

General IconGeneral
BrandMitsubishi Electric
ModelMr. Slim MS09TW
CategoryAir Conditioner
LanguageEnglish

Summary

Safety Precautions

Breaker Operation During Use

Avoid turning the breaker off/on during air conditioner operation to prevent sparks and potential fires.

Preventing Finger Insertion

Never insert fingers or objects into air inlets/outlets to avoid injury from high-speed rotating fan blades.

Professional Repair and Relocation

Customer-performed repairs or relocations can lead to fire, electric shock, or injury; consult a dealer.

Abnormality Handling

If any abnormality like burning smell occurs, stop operation and turn off the breaker immediately.

Customer Installation Prohibition

Customers should not install the unit to prevent fire, electric shock, injury, or water leakage risks.

Handle Filter Removal Carefully

Avoid touching metal parts when removing the air filter to prevent injury.

Avoid Water Cleaning

Do not clean the unit with water as it may enter and cause electric shock.

Battery Safety

Do not charge, disassemble, or throw batteries into fire to prevent leakage, fire, or explosion.

Cleaning Safety

Always switch off and turn off the breaker before cleaning the unit to prevent injury.

Avoid Stepping on Unit

Never step on or place objects on the indoor/outdoor unit to prevent injury from falling.

Stable Maintenance Platform

Use a stable platform for maintenance to avoid injury from falling off unstable surfaces.

Battery Leakage Handling

Wash skin or clothes thoroughly with clean water if exposed to battery leakage.

Avoid Wet Hand Operation

Do not operate switches with wet hands to prevent the risk of electric shock.

Avoid Flammable Sprays

Do not use insecticides or flammable sprays near the unit as it may cause fire or deformation.

Check Installation Stand

Do not use a damaged installation stand as the unit may fall, causing injury.

Proper Grounding

Ground the unit correctly to prevent electric shock, avoiding gas pipes or phone lines.

Flammable Gas Area Installation

Do not install the unit where flammable gas might leak to prevent explosion risk.

GFI Circuit Breaker for Humidity

Use a GFI circuit breaker in high humidity or near water areas for protection against electric shock.

Preparation Before Operation

I FEEL... Auto Operation

I FEEL Mode Operation

Explains how the unit automatically sets mode, temperature, and fan speed based on room conditions.

Maintenance

Before Starting Maintenance

Important safety step: always turn off the breaker before performing any maintenance.

Before Contacting the Serviceman

Troubleshooting: Unit Not Operating

Checks for when the air conditioner cannot be operated.

Troubleshooting: Insufficient Cooling

Checks for when the unit cannot be cooled sufficiently.

Troubleshooting: Remote Display Issues

Checks for when the remote controller display does not appear or signal is not received.

Installation, Relocation and Inspection

Electrical Work Requirements

Use an exclusive circuit, correct voltage/frequency, and specified fuses/breakers.

Customer Installation Warning

Warns against customer installation due to risks of fire, shock, injury, or leakage.

Grounding and GFI

Ensures proper grounding and recommends GFI breakers for humid areas.

Relocation Warning

Highlights that relocation requires special techniques and should be done by professionals.