SERVICE MANUAL
SPLIT-TYPE,HEAT PUMP AIR CONDITIONERS
CONTENTS
1. TECHNICAL CHANGES ····································2
2. PART NAMES AND FUNCTIONS······················3
3. SPECIFICATION·················································6
4. OUTLINES AND DIMENSIONS ·························9
5. WIRING DIAGRAM ··········································12
6. REFRIGERANT SYSTEM DIAGRAM··············20
7. PERFORMANCE CURVES······························24
8. MICROPROCESSOR CONTROL ····················27
9. SERVICE FUNCTIONS ····································34
10. TROUBLESHOOTING······································37
11. DISASSEMBLY INSTRUCTIONS·····················45
12. PARTS LIST······················································53
13. OPTIONAL PARTS···········································61
Wireless type
Models
MS-07NV -
(
WH
)
· MU-07NV -
MS-09NV -
(
WH
)
· MU-09NV -
MS-12NV -
(
WH
)
· MU-12NV -
MS-18NV -
(
WH
)
· MU-18NV -
MS-24NV -
(
WH
)
· MU-24NV -
MS-07NV -
(
WH
)
· MU-07NV -
MS-09NV -
(
WH
)
· MU-09NV -
MS-12NV -
(
WH
)
· MU-12NV -
MS-18NV -
(
WH
)
· MU-18NV -
MS-24NV -
(
WH
)
· MU-24NV -
MS-18NV -
(
WH
)
· MU-18NV -
E3E3
E2E2
E2E2
E2E2
E2E2
E2E2
E1E1
E1E1
E1E1
E1E1
E1E1
No. OB206
MS-18NV -
MS-24NV -
MS-18NV -
MS-24NV -
MS-18NV -
E3
E2
E2
E1
E1
This Servise Manual OB206 deals with MS-07/09/12/18/24NV-E1,
MU-07/09/12/18/24NV-E1, MS-18NV-E2, and MU-18NV-E2 in
OB175 THIRD EDITION issued in June in 1997.
Therfore, please refer to OB206, not to OB175 THIRD EDITION,
for the above models.
OB206t-1.qxp 25/9/97 6:42 PM Page 1

Questions and Answers:

Mitsubishi Electric MU-07NV - E1 Specifications

General IconGeneral
Cooling Capacity2.0 kW
Heating Capacity2.5 kW
Energy Efficiency Ratio (EER)3.21
Coefficient of Performance (COP)3.61
Power Supply220-240 V, 50 Hz
RefrigerantR410A
Weight (Indoor Unit)9 kg
Operating Temperature (Heating)-15°C to 24°C
TypeSplit-System

Summary

Technical Changes

Part Names and Functions

Indoor Unit Components

Identifies and labels parts of the indoor unit, including filters, vanes, and controls.

Outdoor Unit Components

Identifies and labels parts of the outdoor unit, including air inlet, piping, and outlet.

Remote Controller Description

Unit Specifications

Unit Dimensions and Outlines

Indoor Unit Dimensions

Provides detailed measurements and diagrams for the indoor unit's physical size and shape.

Outdoor Unit Dimensions

Shows physical measurements and installation space requirements for the outdoor unit.

Wiring Diagrams

Indoor Unit Wiring

Illustrates the electrical connections and component symbols for the indoor unit.

Outdoor Unit Wiring

Shows the electrical wiring diagram and component symbols for the outdoor unit.

Refrigerant System Diagrams

MS-07/09NV Refrigerant Diagram

Diagram of the refrigerant circuit for MS-07/09NV models, showing key components.

MS-12NV Refrigerant Diagram

Diagram of the refrigerant circuit for MS-12NV models, detailing components and flow.

Evacuation and Air Purge Procedures

Performance Curves and Measurement

Guaranteed Voltage and Air Flow

Specifies voltage tolerance and recommended air flow settings for performance testing.

Main Readings and Measurement Method

Details key parameters and instructions for measuring performance characteristics.

Microprocessor Control Features

Remote Controller Operation

Explains basic operation of the remote controller and the 'I FEEL CONTROL' mode.

I FEEL CONTROL Operation Details

Details 'I FEEL CONTROL' logic, examples, and restart behavior after power interruption.

I FEEL CONTROL Temperature Settings

Describes how initial room temperature affects set temperature in 'I FEEL CONTROL'.

Temperature Control Buttons

Explains the function of TOO WARM and TOO COOL buttons for temperature adjustment.

Cool Mode Operation Details

Details coil frost prevention and time control for the COOL mode of 'I FEEL CONTROL'.

Dry Mode Operation Details

Describes 'I FEEL CONTROL' DRY mode operation based on room temperature.

Fan Operation Modes

Covers FAN mode operation, fan motor control, and speed adjustment.

Auto Vane Operation

Explains vane motor drive, angle control, and auto vane operation modes.

Vane Positioning and Auto Mode

Details vane positioning procedures and the automatic vane angle determination.

Swing, Dew Prevention, and Sleep Modes

Describes swing mode, dew prevention function, and sleep mode operation.

Timer Operation Functions

Setting and Cancelling Timers

Instructions for setting ON/OFF timers and canceling programmed timer operations.

Service Functions

Timer Short Mode

Explains how to shorten timer operation intervals for service purposes.

Remote Controller P.C. Board Modification

Procedure for modifying the remote controller PCB for individual unit operation.

Auto Restart Function

Troubleshooting Guide

Troubleshooting Cautions

Important safety and procedural notes to follow before and during troubleshooting.

Troubleshooting Procedure and Remote Reset

Steps for diagnosing issues and resetting the remote controller.

Troubleshooting Flowchart

Guides diagnosis of unit malfunctions based on operating indicator symptoms.

Troubleshooting Check Table

Lists symptoms, detection methods, and check points for common unit problems.

Main Parts Trouble Criteria

Provides resistance and voltage criteria for testing key unit components.

Indoor Fan Motor Troubleshooting

Specific steps to diagnose and resolve issues with the indoor fan motor.

Receiver P.C. Board Troubleshooting

Diagnoses problems related to the indoor unit's signal receiver P.C. board.

Indoor Control P.C. Board Troubleshooting

Guides troubleshooting for the main indoor electronic control P.C. board.

Outdoor Unit Operation Troubleshooting

Troubleshooting steps for issues with compressor and outdoor fan operation.

Disassembly Instructions - Indoor Unit

Removing the Front Panel

Step-by-step guide with photos for removing the front panel of the indoor unit.

Removing Control Boards

Instructions for safely removing the electronic and display P.C. boards.

Removing Electrical Box and Vane Motor

Procedure for removing the electrical box and the vane motor assembly.

Removing Fan Motor and Line Flow Fan

Steps to remove the indoor fan motor and the line flow fan.

Disassembly Instructions - Outdoor Unit (MU-07/09NV)

Removing the Cabinet and Fan Motor

Guide to removing the outdoor unit cabinet and the fan motor assembly.

Removing the Compressor

Detailed steps for safely removing the compressor from the outdoor unit.

Disassembly Instructions - Outdoor Unit (MU-12/18/24NV)

Removing Cabinet and Electrical Parts

Instructions for removing the outdoor unit cabinet and its electrical components.

Removing Outdoor Fan Motor and Compressor

Steps for removing the outdoor fan motor and the compressor.

Parts List - Indoor Unit

Indoor Unit Structural Parts

List of structural components for the indoor unit with part numbers.

Indoor Unit Heat Exchanger Parts

List of parts related to the indoor unit's heat exchanger.

Indoor Unit Electrical Parts

Catalog of electrical components used in the indoor unit.

Parts List - Outdoor Unit (MU-07/09NV)

Outdoor Unit Structural Parts

List of structural components for the MU-07/09NV outdoor unit.

Outdoor Unit Functional & Electrical Parts

Catalog of functional and electrical parts for MU-07/09NV outdoor units.

Parts List - Outdoor Unit (MU-12NV)

Outdoor Unit Structural Parts

List of structural components for the MU-12NV outdoor unit.

Parts List - Indoor Unit (MS-18/24NV)

Indoor Unit Structural Parts

List of structural components for the MS-18/24NV indoor units.

Indoor Unit Heat Exchanger Parts

Parts list for the heat exchanger components of the indoor unit.

Indoor Unit Electrical Parts

Catalog of electrical parts used in the MS-18/24NV indoor units.

Parts List - Outdoor Unit (MU-18/24NV)

Outdoor Unit Structural Parts

List of structural components for the MU-18/24NV outdoor units.

Optional Parts and Accessories

Remote Controller Parts

Lists the remote controller and its holder as optional accessories.

Optional Refrigerant Pipes

Details optional refrigerant pipe kits, lengths, sizes, and charge requirements.

Filters and Maintenance

Air Cleaning Filter

Information on the air cleaning filter, its life, maintenance, and part number.

Deodorizing Filter

Details about the deodorizing filter, its cleaning, replacement, and part number.