SERVICE MANUAL
CONTENTS
1. TECHNICAL CHANGES ····································2
2. PART NAMES AND FUNCTIONS······················5
3. SPECIFICATION·················································6
4. NOISE CRITERIA CURVES·······························8
5. OUTLINES AND DIMENSIONS ·························9
6. WIRING DIAGRAM ··········································10
7. REFRIGERANT SYSTEM DIAGRAM··············12
8. PERFORMANCE CURVES······························15
9. TROUBLESHOOTING······································23
10. DISASSEMBLY INSTRUCTIONS·····················30
11. PARTS LIST······················································36
Wireless type
Models
MU-GA50VB -
MU-GA60VB -
MU-GA80VB -
E1
E1
E1
SPLIT-TYPE, AIR CONDITIONERS
MU-GA50VB -
E1
Indication of model name
NOTE:
•This service manual describes technical data of outdoor units.
As for indoor units MS-GA50VB - , MS-GA60VB - and MS-GA80VB - , refer to the service
manual OB369.
E1E1E1
No. OB370
HFC
utilized
R410A
OB370-1.qxp 04.10.14 1:45 PM Page 1

Questions and Answers

  • D
    David KaneJul 29, 2025
    What to do if the OPERATION INDICATOR lamp on my Mitsubishi Electric MU-GA50VB is flashing?
    • M
      Mr. Blake CharlesJul 29, 2025
      If the OPERATION INDICATOR lamp on your Mitsubishi Electric Air Conditioner's indoor unit is flashing, it could indicate several issues: * Trouble with the room temperature or indoor coil thermistor: Check the thermistors. * Trouble with the indoor fan motor: Refer to the mentioned check. * Trouble with the indoor unit control system: Replace the indoor electronic control P.C. board. * Trouble with a thermistor in the outdoor unit: Refer to the mentioned check. * Trouble with the outdoor control system: Replace the deicer P.C. board. * Trouble with low discharge temperature protection: Refer to the mentioned check.

Summary

Technical Changes and R410 A Refrigerant

R410 A Refrigerant Comparison

Compares R410A properties with R22, including handling and safety.

Unit Specifications and Performance

Performance Data Tables

Presents detailed cooling performance metrics across various indoor/outdoor conditions.

Wiring Diagrams

Refrigerant System Details

Performance Curves and Graphs

Troubleshooting Guide

Troubleshooting Cautions and Procedures

Lists safety warnings and initial steps for diagnosing unit malfunctions.

Fault Code Diagnosis Flow

Guides technicians through diagnosing specific error codes indicated by the indoor unit lamp.

Component Resistance Checks

Specifies resistance values for critical components to identify failures.

Troubleshooting Flowcharts

Provides detailed step-by-step troubleshooting flows for specific issues.

Disassembly Instructions

Parts List

Mitsubishi Electric MU-GA50VB Specifications

General IconGeneral
BrandMitsubishi Electric
ModelMU-GA50VB
Cooling Capacity5.0 kW
Power Supply220-240 V, 50 Hz
RefrigerantR410A
TypeSplit System