EasyManua.ls Logo

Mitsubishi Electric MUH-A09WV User Manual

Mitsubishi Electric MUH-A09WV
158 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SERVICE MANUAL
CONTENTS
1. TECHNICAL CHANGES ····································2
2. PART NAMES AND FUNCTIONS······················6
3. INDOOR/OUTDOOR
CORRESPONDENCE TABLE ···························8
4. INDOOR UNITS COMBINATION ·······················9
5. SPECIFICATION···············································10
6. NOISE CRITERIA CURVES···························· 17
7. OUTLINES AND DIMENSIONS ······················ 20
8. WIRING DIAGRAM ··········································25
9. REFRIGERANT SYSTEM DIAGRAM··············32
10. PERFORMANCE CURVES······························45
11. MICROPROCESSOR CONTROL·····················84
12. SERVICE FUNCTIONS···································102
13. TROUBLESHOOTING····································104
14. DISASSEMBLY INSTRUCTIONS···················129
15. PARTS LIST····················································144
16. OPTIONAL PARTS·········································157
Wireless type
Models
MSC-A07WV -
(
WH
)
· MU-A07WV -
MSC-A09WV -
(
WH
)
· MU-A09WV -
MSC-A12WV -
(
WH
)
· MU-A12WV -
MSC-A07WV -
(
WH
)
· MUH-A07WV -
MSC-A09WV -
(
WH
)
· MUH-A09WV -
MSC-A12WV -
(
WH
)
· MUH-A12WV -
Multi system type
Models
MSC-A07WV -
(
WH
)
· MUX-A10WV -
MSC-A09WV -
(
WH
)
· MUX-A19WV -
MSC-A12WV -
(
WH
)
· MUX-A20WV -
· MUX-A25WV -
· MUX-A26WV -
Inverter-controlled multi system Model
· MXZ-A18WV -
E1
E1
E1
E1E1
E1E1
E1E1
E1E1
E1E1
E1E1
E1E1
E1E1
E1E1
MSC-A07WV -
MSC-A09WV -
MSC-A12WV -
E1
E1
E1
No. OB307
REVISED EDITION-A
HFC
utilized
R410A
SPLIT-TYPE, AIR CONDITIONERS
SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS
Revision:
MXZ-A18WV - have been added.
MSC-A07/09/12WV - Part No.
.
have changed.
VARISTOR (NR11& NR12)
E02 336 385 E02 749 385
Please void OB307.
E1
E1
Indication of
model name
Remote
controller
OB307A1.qxp 03.2.19 3:56 PM Page 1
All manuals and user guides at all-guides.com
all-guides.com
Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Electric MUH-A09WV and is the answer not in the manual?

Mitsubishi Electric MUH-A09WV Specifications

General IconGeneral
BrandMitsubishi Electric
ModelMUH-A09WV
CategoryAir Conditioner
LanguageEnglish

Summary

Mitsubishi Electric Service Manual Overview

1 Technical Changes

Details on modifications and updates made to the service manual.

R410A Refrigerant Information

Information for Air Conditioner with R410A Refrigerant

Key points for handling R410A refrigerant, including safety and installation.

Tools and Piping for R410A Systems

Tools Dedicated for R410A Refrigerant

Lists specialized tools required for R410A refrigerant systems.

Refrigerant Piping Specifications

Details specifications for refrigerant piping, including material and dimensions.

Refrigerant Oil and Air Purge

Information on refrigerant oil application and air purging procedures.

Additional Refrigerant Charge

Guidelines for additional refrigerant charging.

Part Identification and System Diagrams

2 Part Names and Functions - Indoor Unit

Identifies components and controls of the indoor unit.

Outdoor Unit Part Identification

Identifies components of MU/MUH outdoor units.

Outdoor Unit Part Identification - MUX Series

Identifies components of MUX-A10WV, MUX-A26WV, and MXZ-A18WV outdoor units.

Accessories List

Lists included accessories for the air conditioning system.

Remote Controller and System Configuration

Wireless Remote Controller Overview

Details the functions and buttons of the wireless remote controller.

3 Indoor/Outdoor Correspondence Table

Table showing compatible indoor and outdoor unit combinations.

Indoor Unit Combinations

4 Indoor Units Combination - MXZ-A18WV

Details possible combinations of indoor units with the MXZ-A18WV outdoor unit.

5 Specification Details

Indoor and Outdoor Unit Specifications

Provides detailed technical specifications for indoor and outdoor units.

Noise Criteria Curves

6 Noise Criteria Curves

Presents octave band sound pressure levels for various models.

Outlines and Dimensions

Indoor Unit Dimensions

Provides dimensions for MSC-A07/09/12WV indoor units.

MU Series Outdoor Unit Dimensions

Details dimensions and required space for MU/MUH outdoor units.

MUX Series Outdoor Unit Dimensions

Provides dimensions and required space for MUX-A10WV/A19WV outdoor units.

MUX Series Outdoor Unit Dimensions - Continued

Provides dimensions and required space for MUX-A20WV/A25WV outdoor units.

MUX Series Outdoor Unit Dimensions - Continued

Provides dimensions and required space for MUX-A26WV/MXZ-A18WV outdoor units.

Wiring Diagrams

8 Wiring Diagram - Indoor Unit

Electrical wiring diagram for MSC-A07/09/12WV indoor units.

Outdoor Unit Wiring Diagrams - MU/MUH Series

Electrical wiring diagrams for MU/MUH outdoor units.

Outdoor Unit Wiring Diagrams - MUX Series

Electrical wiring diagrams for MUX-A10WV outdoor units.

Outdoor Unit Wiring Diagrams - MUX Series

Electrical wiring diagrams for MUX-A19WV/A25WV outdoor units.

Outdoor Unit Wiring Diagrams - MUX Series

Electrical wiring diagram for MUX-A20WV outdoor unit.

Outdoor Unit Wiring Diagrams - MUX Series

Electrical wiring diagram for MUX-A26WV outdoor unit.

Outdoor Unit Wiring Diagrams - MXZ Series

Electrical wiring diagram for MXZ-A18WV outdoor unit.

Refrigerant System Diagrams

Refrigerant System Diagram - MSC/MU Single Units

Diagrams showing refrigerant flow for MSC/MU single units.

Refrigerant System Diagram - MSC/MU Single Units

Diagrams showing refrigerant flow for MSC/MU single units.

Refrigerant Piping and Charge Limits

Max Refrigerant Piping Length

Specifies maximum allowed refrigerant pipe lengths.

Max Height Difference

Specifies maximum allowed height difference between units.

Additional Refrigerant Charge (R410A)

Details additional refrigerant charge based on piping length.

Piping and Refrigerant Charge Details

Max Refrigerant Piping Length & Height Difference

Combines piping length and height difference limits.

Additional Refrigerant Charge (R410A)

Details additional refrigerant charge based on piping length.

Piping Preparation Specifications

Shows specifications for commercially available pipes.

Performance Curves

10 Performance Curves Overview

Explains how to interpret performance curves.

10-1 Capacity and Input Curves

Charts showing capacity and input under various conditions.

Outdoor Unit Performance Data

10-2 Outdoor Low Pressure and Current - COOL Operation

Graphs for outdoor low pressure and current for MU models.

10-4 Outdoor Low Pressure and Current - COOL Operation

Graphs for outdoor low pressure and current for MUX models.

Inverter Performance Curves

10-6 Capacity and Input Correction by Inverter Output Frequency

Shows how inverter frequency affects capacity and input.

Single Unit Operation Performance

10-7 Outdoor Low Pressure and Current - 07-class Single Operation

Performance data for 07-class unit single operation.

09-class Unit Single Operation Performance

Performance data for 09-class unit single operation.

12-class Unit Single Operation Performance

Performance data for 12-class unit single operation.

Performance Data Tables

Performance Data - MSC/MU-A07WV Models (Cooling)

Cooling performance data for MSC/MU-A07WV models.

Performance Data - MSC/MU-A09WV Models (Cooling)

Cooling performance data for MSC/MU-A09WV models.

Performance Data - MSC/MU-A12WV Models (Cooling)

Cooling performance data for MSC/MU-A12WV models.

Performance Data - MSC/MUH-A07WV Models (Heating)

Heating performance data for MSC/MUH-A07WV models.

Performance Data - MSC/MUH-A09WV Models (Heating)

Heating performance data for MSC/MUH-A09WV models.

Performance Data - MSC/MUH-A12WV Models (Heating)

Heating performance data for MSC/MUH-A12WV models.

Performance Data - MSC-A07WV / MUX-A10WV Models (Cooling)

Cooling performance data for MSC-A07WV/MUX-A10WV.

Performance Data - MSC-A09WV / MUX-A19WV Models (Cooling)

Cooling performance data for MSC-A09WV/MUX-A19WV.

Performance Data - MSC-A12WV / MUX-A20WV Models (Cooling)

Cooling performance data for MSC-A12WV/MUX-A20WV.

Performance Data - MSC-A09WV / MUX-A19WV Models (Cooling)

Cooling performance data for MSC-A09WV/MUX-A19WV.

Performance Data - MSC-A09WV / MUX-A20WV Models (Cooling)

Cooling performance data for MSC-A09WV/MUX-A20WV.

Performance Data - MSC-A12WV / MUX-A19WV Models (Cooling)

Cooling performance data for MSC-A12WV/MUX-A19WV.

Performance Data - MSC-A12WV / MUX-A20WV Models (Cooling)

Cooling performance data for MSC-A12WV/MUX-A20WV.

Performance Data - MSC-A12WV / MUX-A25WV Models (Cooling)

Cooling performance data for MSC-A12WV/MUX-A25WV.

Performance Data - MSC-A12WV / MUX-A26WV Models (Cooling)

Cooling performance data for MSC-A12WV/MUX-A26WV.

Microprocessor Control Functions

Wireless Remote Controller Operation

Details on using the wireless remote controller for basic operations.

Indoor Unit Display Section

Explanation of the operation indicator lamp on the indoor unit.

11-1 COOL Operation

Procedure for operating the unit in COOL mode.

11-1 Cool Operation - Thermostat Control

How the thermostat controls ON/OFF based on temperature difference.

11-1 Cool Operation - Indoor Fan Speed Control

How indoor fan speed is set by the FAN SPEED CONTROL button.

11-1 Cool Operation - Coil Frost Prevention

Mechanism for preventing coil frost during operation.

11-4 HEAT Operation

Procedure for operating the unit in HEAT mode.

11-4 Heat Operation - Thermostat Control

Thermostat control logic for HEAT mode.

11-4 Heat Operation - Indoor Fan Speed Control

Indoor fan speed control for HEAT mode.

11-4 Heat Operation - Cold Air Prevention Control

Control logic to prevent cold air blow during heating.

Warm Air Control in HEAT Operation

How warm air control adjusts fan speed in HEAT mode.

3 High Pressure Protection

Protection mechanism against high discharge pressure.

4 Defrosting

Description of the defrosting process.

5 R.V. Coil Control

Control logic for the reversing valve (R.V. coil).

11-5 I FEEL CONTROL Operation

Details of the I FEEL CONTROL operation mode.

11-5 I FEEL CONTROL - COOL Mode

Operation specifics for COOL mode in I FEEL CONTROL.

11-5 I FEEL CONTROL - DRY Mode

Operation specifics for DRY mode in I FEEL CONTROL.

11-5 I FEEL CONTROL - HEAT Mode

Operation specifics for HEAT mode in I FEEL CONTROL.

11-6 Fan Motor Control

Explanation of fan motor speed control methods.

11-7 Auto Vane Operation

Details on automatic vane operation and control.

Cold Air Prevention in HEAT Operation

Control to prevent cold air during heating.

11-8 Timer Operation

Instructions for setting timers for unit operation.

11-9 Emergency-Test Operation

Procedure for emergency or test run operations.

11-10 Outdoor Unit Actuator Control

Control status for actuators in various outdoor units.

11-11 Inverter Multi System Control

Control system overview for inverter multi-system units.

11-11-2 Outline of Main Power Supply Circuit

Explanation of the main power supply circuit components and function.

11-12 Optimal Voltage Control

Method for optimizing voltage for compressor efficiency.

11-13 LEV Control

Details on controlling the Linear Expansion Valve (LEV).

LEV Opening Correction by Suction Super Heat

Correction method for LEV opening based on suction super heat.

11-14 Operational Frequency Range

Specifies operational frequency ranges for different modes.

11-15 Heat Defrosting Control

Control logic for initiating and finishing heat defrosting.

11-16 Discharge Temperature Protection Control

Protection control based on discharge temperature.

11-17 Refrigerant Recovery Control on Heating

Procedure for refrigerant recovery during heating.

11-18 Outdoor Fan Control

Details outdoor fan operation in COOL and HEAT modes.

11-19 Relation Between Main Sensor and Actuator

Mapping of sensors to their controlled actuators.

Service Functions and Procedures

12 Service Functions Overview

Introduction to service functions available for the units.

12-1 Compulsory Defrosting Mode for Service

Procedure to initiate compulsory defrosting for servicing.

12-2 Change in Defrost Setting

Instructions for modifying defrost interval and temperature settings.

12-3 Timer Short Mode

Function to shorten timer settings for service purposes.

12-4 P.C. Board Modification for Individual Operation

How to modify P.C. boards for individual indoor unit control.

12-5 Remote Controller Type Setting

Instructions for setting the remote controller type.

12-6 Switch Over and Auto Restart Function

Switching between MU/MUX and MUH/MXZ types and setting auto restart.

Troubleshooting Guide

13 Troubleshooting

General procedures and cautions for troubleshooting.

13-1 Cautions on Troubleshooting

Important precautions before starting troubleshooting.

Servicing Safety Precautions

Safety procedures to follow during servicing.

Battery Replacement

Steps for replacing remote controller batteries.

13-2 Instruction of Troubleshooting

Flowchart for diagnosing common unit issues.

MXZ-A18WV Troubleshooting Flowchart

Troubleshooting flowchart specific to the MXZ-A18WV model.

13-3 Troubleshooting Check Table

Table correlating abnormal symptoms with check points.

MXZ-A18WV Outdoor Unit LED Indicators

Explanation of LED indicators for MXZ-A18WV outdoor unit.

Symptom: Outdoor Unit Operates

Troubleshooting steps when the outdoor unit operates abnormally.

13-4 Trouble Criterion of Main Parts

Criteria for diagnosing common electronic and mechanical parts.

Component Troubleshooting Checks

Check of Remote Controller and Receiver P.C. Board

Troubleshooting steps for remote control communication issues.

Check of Indoor Fan Motor

Diagnostic steps for indoor fan motor problems.

Check of Indoor Electronic Control P.C. Board

Troubleshooting steps for the indoor electronic control board.

Check of Outdoor Unit

Diagnostic steps for issues with the outdoor unit.

Check of Outdoor Unit

Diagnostic steps for outdoor unit operation problems.

Check of Outdoor Unit

Troubleshooting steps when the outdoor unit does not stop.

Check of R.V. Coil

Diagnostic steps for R.V. coil related operation issues.

How to Check Mis-wiring and Serial Signal Error

Steps to diagnose mis-wiring and serial signal communication errors.

Check of Outdoor Thermistor

Diagnostic steps for outdoor unit thermistor abnormalities.

Check of Indoor/Outdoor Units' Connection

Troubleshooting unit connection and cooling issues.

Check of Outdoor Unit Serial Signal

Troubleshooting steps for outdoor unit serial signal issues.

Check of Power Supply

Diagnostic steps for power supply related issues.

Check of R. V. Coil

Diagnostic steps for R.V. coil issues during heating/cooling.

Check of LEV

Diagnostic steps for Linear Expansion Valve (LEV) issues.

Check of Inverter/Compressor

Diagnostic steps for inverter and compressor problems.

Check of Outdoor Fan Motor

Diagnostic steps for outdoor fan motor issues.

Check of Outdoor Unit Thermistor

Diagnostic steps for outdoor unit thermistor issues.

Other Troubleshooting Cases

Troubleshooting for simultaneous operation of different modes.

Test Point Diagrams and Voltage Checks

Test Point Diagram - Indoor Electronic Control P.C. Board

Diagrams showing test points and voltages on the indoor P.C. board.

Disassembly and Component Removal

14 Disassembly Instructions Overview

General instructions and precautions for disassembly.

14-1 Indoor Unit Disassembly

Step-by-step guide for disassembling the indoor unit.

Outdoor Unit Component Removal - MU Series

Steps for removing cabinet and relay panel from MU outdoor units.

Outdoor Unit Component Removal - MUH Series

Steps for removing cabinet and deicer P.C. board from MUH outdoor units.

Outdoor Unit Component Removal - MUX Series

Steps for removing cabinet and relay panel from MUX outdoor units.

Outdoor Unit Component Removal - MUX Series

Steps for removing cabinet from MUX outdoor units.

Outdoor Unit Component Removal - MXZ Series

Steps for removing cabinet and inverter assembly from MXZ unit.

Outdoor Unit Component Removal - MXZ Series

Steps for removing P.C. board and fan motor from MXZ unit.

Outdoor Unit Component Removal - MXZ Series

Steps for removing thermistors from MXZ outdoor unit.

Outdoor Unit Component Removal - MXZ Series

Steps for removing compressor and 4-way valve.

Parts List and Identification

15 Parts List - Indoor Unit Structural Parts

List of structural components for indoor units.

15-2 Accessory and Remote Controller Parts

List of accessories and remote controller parts.

15-3 Indoor Unit Electrical Parts

List of electrical parts and functional components for indoor units.

15-4 Indoor Unit Heat Exchanger

Part number for the indoor unit heat exchanger.

15-5 Outdoor Unit Structural Parts

List of structural components for MU outdoor units.

15-6 Outdoor Unit Electrical Parts

List of electrical parts for MU outdoor units.

15-7 Outdoor Unit Structural Parts

List of structural components for MU outdoor units.

15-10 Outdoor Unit Structural Parts

List of structural components for MUX outdoor units.

15-11 Outdoor Unit Electrical Parts

List of electrical parts for MUX outdoor units.

15-12 Outdoor Unit Structural Parts

List of structural components for MUX outdoor units.

15-13 Outdoor Unit Functional Parts

List of functional parts for MUX outdoor units.

15-14 Outdoor Unit Functional Parts

List of functional parts for MXZ outdoor units.

15-15 Accessory

List of available accessories.

15-16 Outdoor Unit Functional Parts

List of functional parts for MXZ outdoor units.

Filter Maintenance and Optional Parts

15-17 Air Cleaning Filter

Information on air cleaning filter maintenance and replacement.

15-18 Deodorizing Filter

Information on deodorizing filter maintenance and replacement.

16 Optional Parts - Different-Diameter Pipe

Specifications for optional different-diameter piping.

Related product manuals