Do you have a question about the Mitsubishi Electric MUX-A25WV and is the answer not in the manual?
Brand | Mitsubishi Electric |
---|---|
Model | MUX-A25WV |
Category | Air Conditioner |
Language | English |
Specifies requirements for refrigerant pipes, including material and thickness.
Covers air purging and additional refrigerant charging procedures for R410A.
Identifies components of the indoor unit, including filters, vanes, and panels.
Identifies components of the outdoor unit, including air inlet, outlet, and piping.
Lists included accessories for indoor and outdoor units, such as installation plates and remote controllers.
Details specifications for indoor units (MSC-A07WV, MSC-A09WV, MSC-A12WV).
Details specifications for outdoor units (MU-A07WV, MU-A09WV, MU-A12WV).
Presents noise criteria curves for different indoor and outdoor unit models.
Provides dimensions and installation details for indoor units (MSC-A07WV, MSC-A09WV, MSC-A12WV).
Shows dimensions and required space for outdoor units (MU, MUX, MXZ series).
Shows the electrical wiring diagrams for MSC series indoor units.
Electrical wiring diagrams for MU, MUH, MUX, and MXZ series outdoor units.
Diagram showing refrigerant flow for MU indoor units with MSC/MUH outdoor units.
Diagram showing refrigerant flow for MUH indoor/outdoor units.
Specifies maximum piping length and height difference for various models.
Details additional refrigerant charge required based on piping length.
Presents curves showing capacity and input vs. temperature and humidity for various models.
Graphs showing outdoor low pressure and current based on ambient conditions.
Performance data including capacity and input correction by inverter frequency for MXZ-A18WV.
Explains the operation indicator lamp and remote controller functions for COOL mode.
Details operation procedures for DRY and HEAT modes, including fan and compressor control.
Explains fan motor control logic and auto vane operation.
Instructions for timer operations and emergency/test run procedures.
Explains the components and function of the main power supply circuit for the inverter system.
Details optimal voltage control and LEV opening correction methods.
Procedures for compulsory defrosting and modifying defrost settings.
Describes timer shortening for service and PC board modification for individual operation.
Details how to set remote controller type and switch over MU/MUX and MUH/MXZ types.
Important precautions and a general procedure for troubleshooting.
Flowcharts and tables for diagnosing and resolving operational issues.
Flowchart for diagnosing MXZ-A18WV operational problems based on LED indicators and symptoms.
Lists criteria for checking main components like thermistors, motors, and solenoids.
Step-by-step instructions for disassembling the indoor unit.
Instructions for disassembling MU series outdoor units.
Instructions for disassembling MUH series outdoor units.
Instructions for disassembling MUX series outdoor units.
Instructions for disassembling the MXZ-A18WV outdoor unit.
Lists structural parts for indoor units (MSC series).
Lists structural parts for MU series outdoor units.
Lists electrical and functional parts for MUH series outdoor units.
Information on the air cleaning filter, its maintenance, and replacement.
Information on the deodorizing filter, its cleaning, and replacement.
Details specifications for different-diameter pipes used for connecting units.