SERVICE TECHNICAL GUIDE
CONTENTS
1. MSC MICROPROCESSOR CONTROL················6
2. MS MICROPROCESSOR CONTROL················15
3. MSH MICROPROCESSOR CONTROL··············26
4. MSZ-CA MICROPROCESSOR CONTROL········39
5. MSZ-FA MICROPROCESSOR CONTROL ········54
6. MSZ-GA, MSZ-CB
MICROPROCESSOR CONTROL ············72
7. MCF MICROPROCESSOR CONTROL············100
8. MCFH MICROPROCESSOR CONTROL ·········106
9. MFZ MICROPROCESSOR CONTROL ············115
10. MSZ-HA MICROPROCESSOR CONTROL·····127
11. MSZ-GB MICROPROCESSOR CONTROL·····137
12. MXZ MICROPROCESSOR CONTROL···········150
Wireless type Models
Multi system type Models
SPLIT-TYPE, AIR CONDITIONERS
SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS
FLOOR AND CEILING TYPE AIR CONDITIONERS
FLOOR TYPE, HEAT PUMP AIR CONDITIONERS
MSC-CA•VB - · MU-GA•VB -
MSC-CB•VB - · MUH-GA•VB -
MSC-GA•VB -
E
EE
EE
· MXZ-A•VA -
E
MCF-GA
VB
- · MUCF-GA•VB -
MCFH-GA
VB
- · MUCFH-GA•VB -
MFZ-KA
VA
-
E
EE
EE
MS-GA•VB - · MU-GA•VB -
MSH-CA•VB -
MSH-CB•VB -
MSH-GA•VB - · MUH-GA•VB -
MSZ-CA•VB - · MUZ-CA•VB -
MSZ-FA•VA - · MUZ-FA•VA -
· MUZ-FA•VAH -
MSZ-GA•VA - · MUZ-GA•VA -
· MUZ-GA•VAH -
MSZ-CB•VA -
MSZ-HA•VA - · MUZ-HA•VA -
MSZ-GB•VA - · MUZ-GB•VA -
EE
EE
E
E
EE
E
EE
EE
EE
E
E
EE
Wireless type Models
Inverter-controlled multi system type Models
· MUX-A•VB -
E
Wireless type Models
No. OBT06
REVISED EDITION-D
Revision D:
• MXZ-5A100VA - has been added.
E
Please void OBT06 REVISED EDITION-C.
OBT06D--1qxp 07.3.2 9:22 AM Page 1

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Electric MUX-3A63VB and is the answer not in the manual?

Summary

MSC Microprocessor Control

1-5. I Feel Control Operation

Intelligent temperature control based on user preference.

1-9. Emergency; Test Operation

Manual emergency and test operation modes.

MS Microprocessor Control

2-1. I Feel Control Operation

Intelligent temperature control based on user preference.

2-8. Emergency; Test Operation

Manual emergency and test operation modes.

2-9. Expansion Valve Control (LEV Control)

Control of the electronic expansion valve for refrigerant flow.

MSH Microprocessor Control

3-1. I Feel Control Operation

Intelligent temperature control based on user preference.

3-8. Emergency; Test Operation

Manual emergency and test operation modes.

3-9. Expansion Valve Control (LEV Control)

Control of the electronic expansion valve for refrigerant flow.

MSZ-CA Microprocessor Control

4-1. I Feel Control Operation

Intelligent temperature control based on user preference.

4-2. Auto Change Over ··· Auto Mode Operation

Automatic switching between COOL and HEAT modes.

4-9. Emergency; Test Operation

Manual emergency and test operation modes.

4-10. Inverter System Control

Explanation of the inverter power supply circuit.

MSZ-FA Microprocessor Control

5-4. Auto Change Over ··· Auto Mode Operation

Automatic switching between COOL and HEAT modes.

5-8. i-see Control Operation

Sensor-based temperature adjustment for comfort.

5-9. Area ( ) Setting

Setting the sensing area for the i-see sensor.

5-13. Emergency; Test Operation

Manual emergency and test operation modes.

5-14. Inverter System Control

Explanation of the inverter power supply circuit.

5-15. Operational Frequency Control of Outdoor Unit

Controls outdoor unit operating frequency based on conditions.

5-16. Expansion Valve Control (LEV Control)

Control of the electronic expansion valve for refrigerant flow.

MSZ-GA; MSZ-CB Microprocessor Control

6-4. Auto Change Over ··· Auto Mode Operation

Automatic switching between COOL and HEAT modes.

6-9. Emergency; Test Operation

Manual emergency and test operation modes.

6-10. Inverter System Control

Explanation of the inverter power supply circuit.

6-11. Operational Frequency Control of Outdoor Unit

Controls outdoor unit operating frequency based on conditions.

6-12. Expansion Valve Control (LEV Control)

Control of the electronic expansion valve for refrigerant flow.

MCF Microprocessor Control

7-1. I Feel Control Operation

Intelligent temperature control based on user preference.

7-7. Emergency; Test Operation

Manual emergency and test operation modes.

MCFH Microprocessor Control

8-1. I Feel Control Operation

Intelligent temperature control based on user preference.

8-7. Emergency; Test Operation

Manual emergency and test operation modes.

MFZ Microprocessor Control

9-4. Auto Change Over ··· Auto Mode Operation

Automatic switching between COOL and HEAT modes.

9-8. i-save Operation

Energy-saving mode for frequent settings.

9-10. Emergency;Test Operation

Manual emergency and test operation modes.

MSZ-HA Microprocessor Control

10-7. Emergency;Test Operation

Manual emergency and test operation modes.

10-8. Inverter System Control

Explanation of the inverter power supply circuit.

10-9. Operational Frequency Control of Outdoor Unit

Controls outdoor unit operating frequency based on conditions.

MSZ-GB Microprocessor Control

11-4. Auto Change Over ··· Auto Mode Operation

Automatic switching between COOL and HEAT modes.

11-9. Emergency;Test Operation

Manual emergency and test operation modes.

11-10. Inverter System Control

Explanation of the inverter power supply circuit.

MXZ Microprocessor Control

Mitsubishi Electric MUX-3A63VB Specifications

General IconGeneral
BrandMitsubishi Electric
ModelMUX-3A63VB
CategoryAir Conditioner
LanguageEnglish