Do you have a question about the Mitsubishi Electric MXZ-3C24NAHZ and is the answer not in the manual?
Essential safety guidelines and procedures for handling the equipment before and during servicing.
Specific safety rules and cautions for working with R410A refrigerant, including necessary tools.
Lists necessary tools and their specifications for R410A refrigerant service operations.
Instructions for refrigerant piping, covering pipe thickness, flare dimensions, and torque specifications.
Defines the operational temperature limits and guaranteed voltage for various models.
Graphs showing capacity and input correction factors based on temperature and class.
Graphs illustrating outdoor low pressure and unit current at fixed frequencies and dry-bulb temperatures.
Table detailing the relationship between sensors and actuators for various models.
Activates compressor heating to prevent moisture issues and improve startup, consuming approx. 50W.
Detects and corrects wiring/piping errors automatically; provides LED status indications.
Procedure to adjust refrigerant evaporating temperature, with warnings about potential dew drop.
Safety guidelines and preparatory steps before commencing troubleshooting procedures.
Method for recalling and interpreting memorized fault codes via LED indicators.
Visual flowcharts guiding the diagnosis of operational issues based on LED indicators and symptoms.
Comprehensive table mapping LED blink patterns to specific faults, conditions, and remedies.
Detailed diagram of the outdoor control P.C. board showing test points, voltages, and component locations.
Detailed diagram of the outdoor power P.C. board showing test points, voltages, and component locations.
Step-by-step guide with figures for disassembling the cabinet, panels, and components of specific models.
Step-by-step guide with figures for disassembling panels and components of specific models.
Step-by-step guide with figures for disassembling panels and components of specific outdoor units.
| Series | MXZ |
|---|---|
| Type | Multi-Zone Heat Pump |
| HSPF | 10.0 |
| Refrigerant | R410A |
| Indoor Units Supported | 3 |
| Number of Zones | 3 |
| Voltage | 208/230V |
| Outdoor Unit Noise Level | 49 dB(A) |
| Cooling Capacity | 24000 BTU/h |
| Compressor Type | Inverter |
| Power Supply | 1 Phase, 60 Hz |
| Outdoor Unit Dimensions (HxWxD) | 880x840x330 mm |
| Indoor Unit Weight | 10 kg |
| Heating Capacity | 27, 000 BTU/h |
| Indoor Unit Noise Level | Varies by indoor unit model |