EasyManua.ls Logo

Mitsubishi Electric MXZ-3E54VA User Manual

Mitsubishi Electric MXZ-3E54VA
328 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
HFC
utilized
R410A
SERVICE MANUAL
No. OBH723
REVISED EDITION-C
OUTDOOR UNIT
NOTE:
RoHS compliant products have <G> mark
on the spec name plate.
PARTS CATALOG (OBB723)
Models
MXZ-3E54VA
-
E1
,
ET1
,
ER1
MXZ-3E68VA
-
E1
,
ET1
,
ER1
MXZ-4E72VA
-
E1
,
ET1
,
ER1
MXZ-4E83VA
-
E1
,
E2
,
ET1
,
ET2
,
ER1
MXZ-5E102VA
-
E1
,
E2
,
ET1
,
ET2
,
ER1
MXZ-2E53VAHZ
-
E1
,
ER1
MXZ-4E83VAHZ
-
E1
,
ER1
Indoor unit service manual
MSZ-EF•VE Series (OBH589)
MSZ-SF•VA Series (OBH555)
MSZ-SF•VE Series (OBH600)
MSZ-FD•VA Series (OBH488)
MSZ-FH•VE Series (OBH623)
MSZ-GA•VA Series (OB378)
MSZ-GE•VA Series (OBH515)
MSZ-GF•VE Series (OBH634)
MFZ-KA•VA Series (OB409)
MFZ-KJ•VE Series (OBH666)
MLZ-KA•VA Series (OBH483)
SLZ-KA•VA Series (OC320)
SEZ-KD•VA Series (HWE07110)
PLA-RP•BA Series (OCH412)
PCA-RP•KA Series (OCH454)
PEAD-RP•JA Series (HWE08130)
CONTENTS
1. TECHNICAL CHANGES ··································· 3
2. PART NAMES AND FUNCTIONS ····················· 4
3. SPECIFICATION ················································ 5
4. NOISE CRITERIA CURVES ···························· 12
5. OUTLINES AND DIMENSIONS ······················ 14
6. WIRING DIAGRAM ·········································· 20
7. REFRIGERANT SYSTEM DIAGRAM ············· 36
8. PERFORMANCE CURVES ····························· 44
9. ACTUATOR CONTROL ··································· 73
10. SERVICE FUNCTIONS ···································· 74
11. TROUBLESHOOTING ····································· 77
12. DISASSEMBLY INSTRUCTIONS ···················· 97
INDOOR UNITS COMBINATION SHEETS
MXZ-4E83VA
MXZ-5E102VA
MXZ-2E53VAHZ
Please void OBH723 REVISED EDITION-B.
Revision C:
• MXZ-3E54VA-
ER1
, MXZ-3E68VA-
ER1
, MXZ-
4E72VA-
ER1
, MXZ-4E83VA-
E2
,
ET2
,
ER1
,
MXZ-5E102VA-
E2
,
ET2
,
ER1
, MXZ-2E53VAHZ-
ER1
and MXZ-4E83VAHZ-
ER1
have been added.

Other manuals for Mitsubishi Electric MXZ-3E54VA

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Electric MXZ-3E54VA and is the answer not in the manual?

Mitsubishi Electric MXZ-3E54VA Specifications

General IconGeneral
SeriesMXZ
Cooling Capacity5.4 kW
RefrigerantR410A
Voltage (V)220-240
Power Supply Voltage220-240 V
Outdoor Unit Noise Level49 dB(A)
Hertz (Hz)50
Power Supply Frequency50 Hz
PhaseSingle

Summary

1 TECHNICAL CHANGES

3 SPECIFICATION

6 WIRING DIAGRAM

7 REFRIGERANT SYSTEM DIAGRAM

PUMPING DOWN

10 SERVICE FUNCTIONS

10-4. AUTO LINE CORRECTING

10-5. CHANGING THE AMPERE LIMIT

11 TROUBLESHOOTING

11-1. CAUTIONS ON TROUBLESHOOTING

Safety precautions and checks before starting troubleshooting.

11-2. FAILURE MODE RECALL FUNCTION

Memorizes and recalls abnormal conditions that occurred.

3. Outdoor unit failure mode table

Lists failure modes, LED indications, conditions, and remedies.

11-4. TROUBLESHOOTING CHECK TABLE

Details symptoms, LED indications, conditions, and remedies for various failures.

11-5. TROUBLE CRITERION OF MAIN PARTS

Details testing methods and criteria for main components.

How to check miswiring and serial signal error

Troubleshooting steps for miswiring and serial signal errors.

How to check inverter/compressor

Procedure to check the inverter and compressor for proper operation.

11-7. TEST POINT DIAGRAM AND VOLTAGE

Provides diagrams and voltage checks for outdoor control PC board components.

2. Outdoor power P.C. board

Details the outdoor power P.C. board layout and connections.

12 DISASSEMBLY INSTRUCTIONS

1. Removing the cabinet and the panels

Instructions for removing the cabinet and panels of the outdoor unit.

2. Removing P.C. boards and reactor

Instructions for removing the control PC board, reactor, and power PC board.

3. Removing the fan motor

Instructions for removing the outdoor fan motor and propeller fan.

Related product manuals