SERVICE MANUAL
CONTENTS
1. TECHNICAL CHANGES ··································· 2
2. PART NAMES AND FUNCTIONS ····················· 4
3. SPECIFICATION ················································ 5
4. NOISE CRITERIA CURVES ···························· 14
5. OUTLINES AND DIMENSIONS ······················ 17
6. WIRING DIAGRAM ·········································· 21
7. REFRIGERANT SYSTEM DIAGRAM ············· 50
8. PERFORMANCE CURVES ····························· 59
9. ACTUATOR CONTROL ··································· 87
10. SERVICE FUNCTIONS ···································· 88
11. TROUBLESHOOTING ····································· 92
12. DISASSEMBLY INSTRUCTIONS ·················· 121
INDOOR UNITS COMBINATION SHEETS
Models
No. OBH626
REVISED EDITION-F
HFC
utilized
R410A
SPLIT-TYPE AIR CONDITIONERS
OUTDOOR UNIT
Indoor unit service manual
MSZ-EF•VE Series (OBH589)
MSZ-SF•VA Series (OBH555)
MSZ-SF•VE Series (OBH600)
MSZ-FH•VE Series (OBH623)
MFZ-KA•VA Series (OB409)
MFZ-KJ•VE Series (OBH666)
MLZ-KA•VA Series (OBH483)
SLZ-KA•VA Series (OC320)
SEZ-KD•VA Series (HWE07110)
PLA-RP•BA Series (OCH412)
PCA-RP•KA Series (OCH454)
PEAD-RP•JA Series (HWE08130)
NOTE:
RoHS compliant products have <G> mark
on the spec name plate.
PARTS CATALOG (OBB626)
MXZ-2D33VA
MXZ-2D40VA
MXZ-2D42VA
MXZ-2D53VA MXZ-2D53VAH
Please void OBH626 REVISED EDITION-E
MXZ-2D33VA
-
E1
,
E2
,
ER2
,
ET2
MXZ-2D40VA
-
E1
,
ER2
MXZ-2D42VA
-
E2
,
ET2
MXZ-2D53VA
-
E1
,
E2
,
ER2
,
ET2
MXZ-2D53VAH
-
E1
,
E2
,
ER2
MXZ-3D54VA
-
E1
MXZ-3D54VA2
-
E2
,
ER2
,
ET2
MXZ-3D68VA
-
E1
,
E2
,
ER2
,
ET2
MXZ-4D72VA
-
E1
,
E2
,
ER2
,
ET2
MXZ-4D83VA
-
E1
,
E2
,
ER1
,
ER2
,
ET2
MXZ-5D102VA
-
E1
,
E2
,
ER1
,
ER2
,
ET2
Revision F:
MXZ-2D33/2D42/2D53/3D68/4D72/4D83/5D102VA
-
ET2
and MXZ-3D54VA2
-
ET2
have been added.

Other manuals for Mitsubishi Electric MXZ-4D83VA

Questions and Answers

  • M
    mcconnellmichaelAug 8, 2025
    What to do if the Mitsubishi Electric MXZ-4D83VA detects high pressure with the high-pressure switch (HPS) during operation?
    • T
      Tammy FullerAug 8, 2025
      If the high-pressure switch detects high pressure during operation, check the refrigerant circuit and the refrigerant amount. Also, check the stop valve.
  • K
    Katherine CaseyAug 14, 2025
    What should I do if the fin temperature exceeds 90 ºC during operation of my Mitsubishi Electric Air Conditioner?
    • J
      Jenna DixonAug 14, 2025
      If the fin temperature exceeds 90 ºC during operation, check around the outdoor unit and the outdoor unit air passage.
  • C
    Carlos ArnoldAug 20, 2025
    What to do if the discharge temperature exceeds 116 ºC during operation of Mitsubishi Electric MXZ-4D83VA Air Conditioner?
    • C
      Clinton FrenchAug 20, 2025
      If the discharge temperature exceeds 116 ºC during operation, check the refrigerant circuit and the refrigerant amount.
  • T
    twilliamsonAug 27, 2025
    What to do if the sensor circuit of current of compressor shorts or opens during compressor operate of Mitsubishi Electric MXZ-4D83VA?
    • M
      millerdanielAug 27, 2025
      If the sensor circuit of current of compressor shorts or opens during compressor operation, replace the inverter P.C. board.
  • R
    Rebecca ChaseSep 1, 2025
    What to do if Mitsubishi Electric Air Conditioner nonvolatile memory data cannot be read properly?
    • L
      Lauren LoganSep 1, 2025
      If the nonvolatile memory data cannot be read properly, replace the inverter P.C. board.

Summary

Technical Changes

Specifications

Wiring Diagrams

MXZ-2 D Series Wiring Diagrams

Wiring diagrams for MXZ-2D series outdoor units across various revisions.

MXZ-3 D Series Wiring Diagrams

Wiring diagrams for MXZ-3D series outdoor units across various revisions.

MXZ-4 D Series Wiring Diagrams

Wiring diagrams for MXZ-4D series outdoor units across various revisions.

MXZ-5 D Series Wiring Diagrams

Wiring diagrams for MXZ-5D series outdoor units across various revisions.

Refrigerant System Diagram

Pumping Down Procedure

Safe Refrigerant Pumping Down Steps

Detailed procedure for safe refrigerant pumping down during relocation or disposal.

Operating Fixed-Frequency Operation

Test Run Operation Procedure

Procedure for conducting a test run operation and checking performance.

Actuator Control

Sensor-Actuator Relationship

Table mapping sensors to their corresponding actuators and operational purposes.

Service Functions

Automatic Line Correcting Function

Function to automatically detect and correct wiring or piping errors.

Troubleshooting

Troubleshooting Cautions

Essential safety precautions and checks before starting troubleshooting.

Failure Mode Recall Function

Procedure to retrieve and interpret error codes and failure modes.

Troubleshooting Flowcharts

Flowcharts for diagnosing common outdoor unit issues.

Main Parts Troubleshooting Criteria

Criteria for testing resistance and voltage of key electronic components.

Test Point Diagram and Voltage

Inverter P.C. Board Test Points

Diagrams showing test points and voltage measurements on the inverter P.C. board.

Outdoor Control P.C. Board Test Points

Diagrams showing test points and voltage measurements on the outdoor control P.C. board.

Outdoor Power P.C. Board Test Points

Diagrams showing test points and voltage measurements on the outdoor power P.C. board.

Outdoor Display P.C. Board Test Points

Diagrams showing test points and voltage measurements on the outdoor display P.C. board.

Disassembly Instructions

Mitsubishi Electric MXZ-4D83VA Specifications

General IconGeneral
BrandMitsubishi Electric
ModelMXZ-4D83VA
CategoryAir Conditioner
LanguageEnglish

Related product manuals