CYLINDER UNIT OPTIONAL PARTS
IMMERSION HEATER (1Ph 3kW)
PAC-IH03V2-E
WARNING
●
●
●
●
●
INSTALLATION MANUAL
If the cylinder has already been connected to the power supply ensure circuit breaker is off before carrying out electrical
work.
If the immersion heater is installed incorrectly or modified after installation by the user, water leakage, electric shock or
fire may result.
All electrical work should be performed by a qualified technician according to local regulations and the instructions given
in this manual.
The immersion heater must be powered by a dedicated power supply and the correct voltage and correctly sized circuit
breakers must be used.
Connections must be made securely and without tension on the terminals.
The included component parts of the PAC-IH03V2-E IMMERSION HEATER (1Ph 3kW) shall be used only for the
purposes indicated in the installation manual.
● Before starting installation, read the following description together with the installation manual included with the cylinder unit.
● Please read carefully and observe fully the following safety precautions.
Precaution that must be observed to prevent injuries or death.
WARNING
After installation carry out a test run to ensure correct operation, then explain operation method and safety precautions to the
end user.
Tell your customers to keep this installation manual together with the operation manual, and when they give or sell this
machine to any other person include this installation manual and operation manual with it.
●
Optional parts
D-25
Immersion Heater
3
Optional parts
Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Electric PAC-IH03V2-E and is the answer not in the manual?

Summary

Installation Manual Overview and Safety

General Safety Precautions

Essential safety measures to prevent injuries or death during installation.

Component Identification

Parts List and Diagram

Detailed list and visual representation of all included parts for the immersion heater.

Installation Procedure Steps

Initial Preparation and Thermostat Installation

Steps covering front panel removal, thermostat placement, and securing components.

Electrical Connections and Wiring

Guidance on aligning terminal blocks and connecting wires for the immersion heater.

Final Installation and Checks

Lead Wire Routing and Securing

Instructions for running and fastening lead wires, using bands, and sealing terminals.

Water Filling and Leak Check

Procedures for filling the tank with water and verifying no leaks around the heater.

Overview

The MITSUBISHI ELECTRIC CYLINDER UNIT OPTIONAL PARTS IMMERSION HEATER (1Ph 3kW), model PAC-IH03V2-E, is an optional component designed to enhance the functionality of a cylinder unit by providing an additional heating source. This immersion heater operates on a single-phase, 3kW power supply, making it suitable for residential or light commercial applications where supplementary water heating is required.

Function Description:

The primary function of the PAC-IH03V2-E immersion heater is to heat the water within a cylinder unit. It works by converting electrical energy into heat, which is then transferred directly to the water. This allows for independent or supplementary heating of domestic hot water (DHW), offering flexibility and potentially increased hot water availability. The unit is designed to be integrated into an existing cylinder system, providing an alternative or backup heating method to the main heating source of the cylinder unit.

Important Technical Specifications:

  • Power Supply: 1-Phase, 3kW. This specification indicates the electrical requirements and heating capacity of the unit. A 3kW rating suggests a moderate heating capability, suitable for typical household hot water demands.
  • Model Number: PAC-IH03V2-E. This unique identifier helps in identifying the specific product and its compatibility with various cylinder units.
  • Components: The installation manual lists a comprehensive set of components, ensuring a complete installation package. Key components include:
    • Immersion heater (1 piece): The core heating element.
    • Thermostat (High limit thermal cut-out) (1 piece): A crucial safety feature that prevents overheating by cutting off power if the water temperature exceeds a safe limit.
    • Earth leakage breaker (1 piece): Provides electrical safety by detecting and interrupting current leakage to earth, protecting against electric shock.
    • Relay (1 piece): An electrical switch that controls the power supply to the immersion heater, often used in conjunction with a thermostat or control system.
    • Lead wires (various lengths and colors): For electrical connections within the unit and to the power supply.
    • Water-proof cover and seals: Essential for protecting electrical connections from moisture and ensuring the integrity of the cylinder unit.
    • Fasteners, screws, bands, and labels: For secure installation and clear identification of components.
  • Safety Features: The inclusion of a thermostat with a high limit thermal cut-out and an earth leakage breaker highlights a strong emphasis on safety. These components are designed to prevent electrical hazards and overheating, ensuring reliable and safe operation.

Usage Features:

  • Supplementary Heating: The immersion heater can be used as a supplementary heating source, providing additional hot water when the primary heating system is insufficient or unavailable.
  • Independent Operation: In some setups, the immersion heater can operate independently, offering a standalone solution for hot water generation. This can be particularly useful during periods when the main heating system is not in use, such as in summer months.
  • Integration with Cylinder Unit: The design ensures seamless integration with compatible Mitsubishi Electric cylinder units. The installation process involves fitting the heater into designated pockets and connecting it to the unit's control system.
  • User-Friendly Installation: While electrical work requires a qualified technician, the manual provides clear, step-by-step instructions for assembly and connection, including diagrams for component placement and wiring.
  • DIP Switch Configuration: The manual indicates a DIP switch setting for "1-4 OFF → ON (without immersion heater → with immersion heater)," suggesting that the cylinder unit's control system needs to be configured to recognize the presence of the immersion heater. This allows for proper management and control of the heating element.

Maintenance Features:

  • Qualified Technician Requirement: All electrical work, including installation and any subsequent maintenance, must be performed by a qualified technician in accordance with local regulations. This ensures safety and proper functioning of the unit.
  • Regular Checks: Although not explicitly detailed as maintenance, the initial installation instructions emphasize checking for water leaks and ensuring secure connections. These checks are crucial for preventing future issues and are indicative of good maintenance practices.
  • Component Replacement: The detailed list of components suggests that individual parts, such as the thermostat or lead wires, could be replaced if necessary, extending the lifespan of the overall unit.
  • Water-Proofing: The use of water-proof covers and seals is a key design feature that contributes to the longevity and reliability of the electrical components by protecting them from moisture, thereby reducing the need for frequent maintenance related to water damage.
  • Post-Installation Test Run: The manual explicitly states the need for a test run after installation to ensure correct operation. This is a vital step in verifying the proper functioning of the immersion heater and identifying any potential issues early on.
  • Documentation Retention: Users are advised to keep the installation manual together with the operation manual. This ensures that all necessary information for future reference, troubleshooting, or maintenance is readily available.

In summary, the PAC-IH03V2-E immersion heater is a robust and safety-conscious optional component designed to provide efficient and reliable supplementary or independent hot water heating for compatible cylinder units. Its comprehensive set of components, detailed installation instructions, and integrated safety features make it a valuable addition to a domestic hot water system.

Mitsubishi Electric PAC-IH03V2-E Specifications

General IconGeneral
BrandMitsubishi Electric
ModelPAC-IH03V2-E
CategoryHeater
LanguageEnglish

Related product manuals