5 SPECIFICATIONS
A
A
kW
W
kW
*
/min(CFM
)
dB
dB
mm(in.)
mm(in.)
mm(in.)
kg(lbs)
kg(lbs)
L
mm(in.)
mm(in.)
Power supply (phase, cycle, voltage)
Running current
Max. current
External finish
Refrigerant control
Compressor
Model
Motor output
Starter type
Protection devices
Crankcase heater
Heat exchanger
Fan Fan(drive) % No.
Fan motor output
Airflow
Defrost method
Noise level
Dimensions
Weight
Refrigerant
Charge
Oil (Model)
Pipe size O.D.
Connection method
Between the indoor &
outdoor unit
Mode
Cooling
Heating
W
D
H
Liquid
Gas
Indoor side
Outdoor side
Height difference
Piping length
Service Ref.
PUHZ-P100VHA2.UK
PUHZ-P100VHA3.UK
PUHZ-P100VHA3R1.UK
PUHZ-P100VHA3R2.UK
Cooling
12.26
Munsell 5Y 7/1 / Munsell 3Y 7.8/1.1 (VHA3R1 / R2)
Linear Expansion Valve
Hermetic
TNB220FLHMT
2.9
Inverter
Plate fin coil
Propeller fan % 1
0.060
60(2120)
Reverse cycle
50
54
950(37-3/8)
330+30(13+1-3/16)
943(37-1/8)
75(165)
R410A
3.0(6.6)
0.87(FV50S)
9.52(3/8)
15.88(5/8)
Flared
Flared
Max. 30m
Max. 50m
Heating
12.62
HP switch
Discharge thermo/Comp. surface thermo (VHA3R2)
Single, 50Hz, 230V
OUTDOOR UNIT
REFRIGERANT PIPING
28
A
A
kW
W
kW
*
/min(CFM
)
dB
dB
mm(in.)
mm(in.)
mm(in.)
kg(lbs)
kg(lbs)
L
mm(in.)
mm(in.)
Power supply (phase, cycle, voltage)
Running current
Max. current
External finish
Refrigerant control
Compressor
Model
Motor output
Starter type
Protection devices
Crankcase heater
Heat exchanger
Fan Fan(drive) % No.
Fan motor output
Airflow
Defrost method
Noise level
Dimensions
Weight
Refrigerant
Charge
Oil (Model)
Pipe size O.D.
Connection method
Between the indoor &
outdoor unit
Mode
Cooling
Heating
W
D
H
Liquid
Gas
Indoor side
Outdoor side
Height difference
Piping length
Service Ref. PUHZ-P100VHA4.UK
Cooling
13.98
Munsell 3Y 7.8/1.1
Linear Expansion Valve
Hermetic
TNB220FLHMT
2.9
Inverter
Plate fin coil
Propeller fan % 1
0.060
60(2120)
Reverse cycle
50
54
950(37-3/8)
330+30(13+1-3/16)
943(37-1/8)
75(165)
R410A
3.0(6.6)
0.87(FV50S)
9.52(3/8)
15.88(5/8)
Flared
Flared
Max. 30m
Max. 50m
Heating
14.70
HP switch
Comp. surface thermo
Single, 50Hz, 230V
OUTDOOR UNIT
REFRIGERANT PIPING
28
OCH415G

Table of Contents

Other manuals for Mitsubishi Electric PUHZ-P125YHA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Electric PUHZ-P125YHA and is the answer not in the manual?

Mitsubishi Electric PUHZ-P125YHA Specifications

General IconGeneral
BrandMitsubishi Electric
ModelPUHZ-P125YHA
CategoryAir Conditioner
LanguageEnglish

Related product manuals