Do you have a question about the Mitsubishi Electric PUHZ-RP200YKAR1 and is the answer not in the manual?
Brand | Mitsubishi Electric |
---|---|
Model | PUHZ-RP200YKAR1 |
Category | Air Conditioner |
Language | English |
Lists service manuals for various indoor units and their corresponding service reference numbers.
Emphasizes disconnecting all supply circuits before accessing terminals.
Provides specific cautions for units utilizing R410A refrigerant.
Pre-charged refrigerant supplied for piping length at shipment, simplifying installation.
Function to detect refrigerant leakage over a long period of use for specific models.
Lists refrigerant charge amounts for various models based on piping length.
Details how to calculate additional refrigerant charge based on piping length for specific models.
Provides technical data for compressors, including winding resistance.
Presents noise level data in octave band sound pressure levels for different models.
Lists standard operation data (capacity, input, pressures, temperatures) for various models.
Details requirements for securing the unit with foundation bolts.
States that piping and wiring connections are made from the rear direction only.
Explains how to attach a conduit using a metal plate and screws.
Specifies electrical wiring requirements, including wire size and circuit ratings for power supply.
Details connection patterns for separate indoor and outdoor unit power supplies.
Specifies cable requirements and maximum lengths for indoor-outdoor connections.
Provides guidelines and precautions for M-NET wiring installations.
Provides a summary of actions for recurring and non-recurring troubles, based on error code display.
Lists essential checks to perform before starting a test run for troubleshooting.
Explains how to access and interpret self-diagnosis information from the remote controller.
Details how to handle problems during operation, including error code display.
Explains how to recall error code history during maintenance or service.
Provides a procedure to diagnose remote controller malfunctions and communication issues.
Describes how to perform malfunction diagnosis using the wireless remote controller.
Lists error codes and corresponding actions for diagnosing abnormalities detected when power is applied.
Provides troubleshooting steps based on observed phenomena and their potential causes.
Guides through troubleshooting the "PLEASE WAIT" display issue on the remote controller.
Provides a diagnostic flow for troubleshooting when the remote controller displays nothing.
Details function settings for different indoor unit numbers and system types.
Explains the procedure for selecting functions using the wired remote controller.
Details how to select functions using the wireless remote controller.
Covers various settings for the remote controller, including language and display options.
Explains how to access and view operation data using the remote controller's service monitor.
Lists request codes and their corresponding descriptions for monitoring operation data.
Provides instructions for entering and using maintenance mode via the remote controller.
Details how to check and interpret operation conditions using temperature data and graphs.
Explains the initial settings required to enable the refrigerant leakage detection function.
Step-by-step instructions for removing the top, service, front, and back panels.
Instructions for removing the fan motor and its components.
Details on removing the electrical parts box and its connectors.
Instructions for removing the outdoor 2-phase pipe thermistor (TH6).
Instructions for removing the outdoor thermistor (TH7).
Instructions for removing outdoor pipe, discharge, and shell thermistors.
Instructions for removing the 4-way valve coil and LEV coils.
Instructions for removing the 4-way valve.
Instructions for removing the linear expansion valve.
Instructions for removing the high pressure switch.
Instructions for removing the compressor.
Instructions for removing the power receiver.