EasyManua.ls Logo

Mitsubishi Electric PUHZ-SW120VHA User Manual

Mitsubishi Electric PUHZ-SW120VHA
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SERVICE MANUAL
CONTENTS
1. REFERENCE MANUAL
..................................
2
2. SAFETY PRECAUTION
..................................
3
3. FEATURES
......................................................
7
4. SPECIFICATIONS
...........................................
8
5. DATA
.............................................................
11
6. OUTLINES AND DIMENSIONS
....................
13
7. WIRING DIAGRAM
.......................................
15
8. WIRING SPECIFICATIONS
..........................
18
9.
REFRIGERANT SYSTEM DIAGRAM
...............
19
10. TROUBLESHOOTING
...................................
21
11. DISASSEMBLY PROCEDURE
.....................
65
No.OCH533
REVISED EDITION-A
SPLIT-TYPE, AIR TO WATER HEAT PUMP
R410A
October 2012
PUHZ-SW75VHA.UK
PUHZ-SW75VHA-BS.UK
Salt proof model
PUHZ-SW75VHA-BS
PUHZ-SW100VHA-BS
PUHZ-SW100YHA-BS
PUHZ-SW120VHA-BS
PUHZ-SW120YHA-BS
Note:
• This manual describes
only service data of the
outdoor units.
PUHZ-SW75VHA-BS.UK
PUHZ-SW100VHA-BS.UK
PUHZ-SW100YHA-BS.UK
PUHZ-SW120VHA-BS.UK
PUHZ-SW120YHA-BS.UK
Outdoor unit
[Model names]
PUHZ-SW75VHA
PUHZ-SW100VHA
PUHZ-SW100YHA
PUHZ-SW120VHA
PUHZ-SW120YHA
[Service ref.]
PUHZ-SW75VHA.UK
PUHZ-SW100VHA.UK
PUHZ-SW100YHA.UK
PUHZ-SW120VHA.UK
PUHZ-SW120YHA.UK
PARTS CATALOG (OCB533)
Revision:
The function description of
SW7-3, 7-4 and 7-5 (Page
52) have been corrected
in
REVISED EDITION-A.
Please void OCH533.

Table of Contents

Other manuals for Mitsubishi Electric PUHZ-SW120VHA

Questions and Answers:

Mitsubishi Electric PUHZ-SW120VHA Specifications

General IconGeneral
BrandMitsubishi Electric
ModelPUHZ-SW120VHA
CategoryHeat Pump
LanguageEnglish

Summary

Reference Manual

Indoor Unit Service Manual

Details for indoor unit service procedures.

Safety Precautions

Always Observe for Safety

Essential safety rules for all service operations.

Cautions Related to New Refrigerant

Specific warnings for R410A refrigerant handling.

Cautions for Refrigerant Piping Work

Important considerations for R410A refrigerant piping installation.

Data

Refilling Refrigerant Charge (R410A : kg)

Refrigerant charge amounts based on piping length.

Wiring Specifications

Field Electrical Wiring (power wiring specifications)

Electrical wiring requirements and specifications for outdoor units.

Troubleshooting

Troubleshooting

General guidance for diagnosing and resolving issues.

Check Point Under Test Run

Pre-test run checks and procedures.

Self-Diagnosis Action Table

Error codes and corresponding troubleshooting actions.

Disassembly Procedure

1. Removing the Service Panel and Top Panel

Steps for accessing internal components by removing panels.